A. Khodabakhshian
Faculty of Engineering, Isfahan University, Isfahan, Iran
ABSTRACT
A new method to tune the controller parameters is presented in study for Automatic Generation Control (AGC) of hydro turbine power systems. The controller parameters are adjusted such that the maximum phase is located on the right-most point of the ellipse, corresponding the maximum peak resonance on the Nichols chart. For this system making the open-loop frequency response curve tangent to a specified ellipse is an efficient method for controlling the overshoot, the stability and the dynamics of the system. The robustness of the feedback PID controller has been investigated on a multimachine power system model and the results are shown to be consistent with the expected performance. The results are also compared with a conventional PI controller and shown to be superior; especially since the transient droop compensator of the speed governor is removed a much faster response is obtained. The region of acceptable performance for the LFC covers a wide range of operating and system conditions.
PDF References Citation
How to cite this article
A. Khodabakhshian, 2007. A New Systematic Procedure to Design an Automatic Generation Controller. Journal of Applied Sciences, 7: 3381-3390.
DOI: 10.3923/jas.2007.3381.3390
URL: https://scialert.net/abstract/?doi=jas.2007.3381.3390
DOI: 10.3923/jas.2007.3381.3390
URL: https://scialert.net/abstract/?doi=jas.2007.3381.3390
REFERENCES
- Dash, P.K., A.C. Liew and B.R. Mishra, 1998. An adaptive PID stabilizer for power systems using fuzzy logic. Elect. Power Syst. Res., 44: 213-222.
Direct Link - Gross, G. and J.W. Lee, 2001. Analysis of load frequency control performance assessment criteria. IEEE Trans. Power Syst., 16: 520-525.
Direct Link - Lim, K.Y., Y. Wang and R. Zhou, 1996. Robust decentralized load-frequency control of multi-area power systems. Proc. Inst. Elect. Eng. Gen. Trans. Dist., 143: 377-386.
Direct Link - Liu, F., Y.H. Song, J. Ma, S. Mei and Q. Lu, 2003. 200Optimal load frequency control in restructured power systems. IEE Proc. Gener. Trans. Distrib., 150: 87-95.
Direct Link - Poulin, E. and A. Pomerleau, 1997. Unified PID design method based on a maximum peak resonance specification. IEE Proc. Control Theor. Applied, 144: 566-574.
Direct Link - Rerkpreedapong, D., A. Hasanovis and A. Feliachi, 2003. Robust load frequency control using genetic algorithms and linear matrix inequalities. IEEE Trans. Power Syst., 18: 855-861.
Direct Link - Stankovic, A.M., G. Tadmor and T.A. Sakharuk, 1999. On robust control analysis and design for load frequency regulation. IEEE Trans. Power Syst., 13: 449-455.
Direct Link - Tang, T.C., Z.T. Ding and H. Yu, 2002. Decentralized power system load frequency control beyond the limit of diagonal dominance. Elect. Power Energy Syst., 24: 173-184.
Direct Link