Pharmacokinetic Analysis of Warfarin in Iranian Warfarin Sensitive Patients

S. Sadrai
Faculty of Pharmacy, Tehran University/Medical Sciences, Tehran, Iran

P. Ghadam
Department of Biochemistry, Faculty of Sciences, Alzahra University, Tehran, Iran

R. Sharifian
Department of Hematology, Tehran University/Medical Sciences, Imam Hospital, Tehran, Iran

E. Nematipour
Department of Cardiology, Tehran University/Medical Sciences, Imam Hospital, Tehran, Iran

Z. Kianmehr
Department of Biochemistry, Faculty of Sciences, Alzahra University, Tehran, Iran

Sh. Shahriari
Department of Biochemistry, Faculty of Sciences, Alzahra University, Tehran, Iran

ABSTRACT


In this study, we investigated pharmacokinetic of warfarin in sensitive and control patients by HPLC. The analysis performed by HPLC consisted of a column (Perfectsil Target, 5 μm, 125x4.0 mm) and an isocratic mobile phase of methanol: acetonitrile: phosphate buffer (pH: 3.5) (7:55:38, v/v), flow rate: 1 mL min-1 and UV detection at 270 nm. The assay was linear in warfarin concentration ranges of 0.1-10 μg mL-1 (r2 = 0.9975) and with Relative Standard Deviation (RSD) of <8% for inter-day and <6% for intra-day. The mean warfarin blood concentration of 54 patients was 1.2 ± 0.6 μg mL-1.
PDF Abstract XML References Citation

Keywords


  • warfarin sensitivity
  • pharmacokinetics
  • warfarin
  • HPLC

How to cite this article

S. Sadrai, P. Ghadam, R. Sharifian, E. Nematipour, Z. Kianmehr and Sh. Shahriari, 2008. Pharmacokinetic Analysis of Warfarin in Iranian Warfarin Sensitive Patients. International Journal of Pharmacology, 4: 149-152.

DOI: 10.3923/ijp.2008.149.152

URL: https://scialert.net/abstract/?doi=ijp.2008.149.152

INTRODUCTION


Individuals vary widely in their response to pharmacologic agents and such variability can have profound health effects. Little is known about drug-specific genetic differences, which lead to differential effects of commonly prescribed agents. Warfarin is the most commonly prescribed oral anticoagulant drug for the prophylaxis and treatment of venous and arterial thromboembolic disorders and is being prescribed to an increasing number of patients (Hirsh et al., 1998, 2001). Following initiation of warfarin therapy, major bleeding episodes occur in approximately 12% of patients and death results in as many as 2% of patients (Levine et al., 2001). Overall, the bleeding rate is 7.6 to 16.5 per hundred patient-years. Major or life-threatening bleedings occur at a rate of 1.3 to 2.7 per hundred patient-years. Although major bleeding can occur at therapeutic levels, the risk of bleeding rises with increasing intensity of anticoagulation (Van der Meer et al., 1993; Cannegieter et al., 1995). The effectiveness and safety of warfarin therapy is critically dependent on maintaining the prothrombin and time expressed as the International Normalized Ratio (INR), which is a ratio of the time required for the patient`s blood to coagulate relative to a standardized coagulation time, within the desired therapeutic range (Sconce et al., 2005). Identification of risk factors for the development of a high INR may identify patients at high risk of bleeding because the risk of bleeding increases with increasing intensity of anticoagulation (Taube et al., 2000). The target INR level will vary from case to case dependent upon the clinical indicators, but tends to be two-three in most conditions (Ansell et al., 2001).

Thus, Warfarin treatment is problematic because the dose requirement for warfarin is highly variable, both inter-individually and inter-ethnically. Asian populations require a much lower maintenance dose than Caucasians and Hispanics (Takahashi et al., 2003; Zhao et al., 2004), for which the mechanisms remain elusive. The result of this variability is that some patients require less warfarin dose than others, warfarin sensitive patients and some of them need more warfarin dose, warfarin resistant patients. Variability in warfarin-dose requirement can be influenced by many factors such as pharmacokinetics factors (due to differences in absorption or metabolic clearance of warfarin induced by drug interaction or patient base situation such as gender), pharmacodynamic factors (due to differences in the homeostatic response to given concentrations of warfarin) (Modi et al., 2005; Depr´e et al., 2005) and pharmacogenetics factors (due to mutations in genes such as CYP2C9, VKORC1, etc).

In this study, after optimizing the chromatographic conditions, a rapid and simple HPLC method was developed for the determination of blood warfarin. A single precipitation method with cold acetonitrile was sufficient to eliminate interferences. The total HPLC run-time was relatively short (5 min). Warfarin plasma concentration was determined in 54 patients on warfarin therapy by the method described and the impact of warfarin concentration was investigated.

MATERIALS AND METHODS


Materials: Sodium warfarin (99.9%) was kindly provided by Pharmaceutical Division of Tehran University/Medical Sciences. HPLC grade methanol (PAI Panreac), acetonitrile and potassium dihydrogen phosphate (Merck, Darmstadt, Germany 2007).

Patients` population: Fifty-four treated patients with warfarin were recruited from Imam Hospital (Tehran-Iran) for participation in this trial. The study group clinically sensitive patients (19 patients) were selected and referred by participating centers according to the following criteria:

•Adult-patients who need less than 10.5 mg/week of warfarin to keep the INR in therapeutic range (INR = two-three) (Linder, 2001).

•Patients had been used usual dosage of warfarin (5-15 mg day-1) but they had INR>4 even in seven days after cessation of warfarin or three days after receiving 3 mg day-1 vitamin K1 (the criterion in Imam Hospital).

The control group (35 adult patients) was selected randomly from patients taking warfarin for various cases and showed normal response to warfarin.

Characteristics recorded included age, gender, weight, height, etc. To qualify for participation in the study, clotting factors FIX, FVI, FVII, FV, FII measured in order to assurance from correct function liver and clotting factors were performed on all patients. Among the 54 investigated patients, 25 patients were male, 29 patients were female and some of them with the symptom of arterial fibrillation or history of embolism, cardiac disease, replacement heart valves, etc.

Patient blood samples were collected into tubes containing EDTA. The samples were kept at -70 °C unless they were analyzed in the same day.

Standard preparation: Stock solution of warfarin was prepared at 1 mg mL-1 in methanol. Working solution was diluted from the stock solution to 100 μg mL-1 with distilled water. The concentrations for the standard curve were freshly prepared before the analysis. For the standard curve, blood samples were spiked with warfarin working solution to make final concentrations of 0.1-10 μg mL-1.

Sample preparation and extraction: One thousand microliters of cold acetonitrile (20 min in -20 °C) was added to 500 μL spiked or patient blood. The samples were rigorously vortexes in 5 min and centrifuged at 8000 g for 10 min to separate the percipient. The upper phase was transferred into 1.5 mL tubes and centrifuged another time with the above conditions. Then 100 μL distilled water was added to 200 μL from supernatant and 50 μL of it was injected.

Chromatography: The chromatographic system consisted of Waters 600 pump, Waters 486 UV detector, reversed phase C18 column (Perfectsil Target ODS-3, 5 μm, 125x4.0 mm) and an isocratic mobile phase of methanol: acetonitrile: phosphate buffer (pH: 3.5) (7:55:38, v/v). The flow rate was 1 mL min-1. Data analysis and valley-to-valley integration was performed with Autochoro 2000 1.0 (Younglin Instrument, Korea). The absorbance was analyzed at 270 nm, sensitivity of 0.001 AUFS (Absorbance Units Full Scale) with a total run-time of 5 min.

Method validation: Blood was spiked with known amounts of warfarin in triplicates (n = three). The linearity of the method was established and was then used for analysis of patient samples. The limit of detection (LOD) was defined as the concentration corresponding to a signal to noise ratio of three: one. The limit of quantification (LOQ) was defined as 10xLOD. Recovery was calculated from blood spiked with warfarin at three levels (0.5, 1 and 5.0 μg mL-1) (n = three at each level) in compare to similar aqueous spiked samples. Intra-day and inter-day assay variations were calculated from blood spiked with warfarin at three levels (0.5, 1 and 5.0 μg mL-1) (n = three at each level) run in the same day and in three different days, respectively.

RESULTS AND DISCUSSION


Plasma or blood warfarin measurement is considered helpful to the management of prescription of the drug for patients. The most often used methods for plasma warfarin concentration determination so far described are based on extraction of warfarin from plasma followed by reversed-phase HPLC and the extraction is the critical step, which requires careful conditions to ensure good recovery of warfarin before sample injection. In this way, several HPLC methods with UV detectors were described for determination of warfarin concentration in plasma (Andalibi et al., 1998; Lombardi et al., 2003; Sun et al., 2006).

In this study, we developed a HPLC method for quantification of warfarin in blood and investigated the

Image for - Pharmacokinetic Analysis of Warfarin in Iranian Warfarin Sensitive Patients
Fig. 1: Warfarin calibration curve. AU, absorbance unit. Equation describing the relationship: Y = 21.843x +2.0104; r2 = 0.9975

Table 1: Blood warfarin concentration in sensitive and normal patients
Image for - Pharmacokinetic Analysis of Warfarin in Iranian Warfarin Sensitive Patients

blood warfarin concentration for the patients. The method has several advantages. It is sensitive, reliable, rapid, cost-efficient and easy to perform and the most important characterization is single precipitation method with cold acetonitrile was sufficient to eliminate interferences.

A typical calibration curve (peak area as absorbance unit vs. warfarin concentration) is shown in Fig. 1 with a good linearity (r2 = 0.9975). Due to loop system, injection internal standard was not used. Chromatograms correspondent to the samples containing warfarin at 5 μg mL-1, the blank sample and a patient sample are shown in Fig. 2 . The mean recovery, estimated by measuring warfarin concentration in three different assays for a drug-free blood sample pooled from healthy subjects and spiked with warfarin at the final concentration of 0.5, 1 and 5 μg mL-1 is 124.6%. The precision and reproducibility of the assay, which was estimated as relatively standard deviation is <8% for inter-day and <6% for intra-day at the concentration of 0.1-10 μg mL-1. The limit of detection in human plasma was 20 ng mL-1 for warfarin. Limit of quantification defined was calculated to 200 ng mL-1.

The results were determined for the 54 patients (19 sensitive and 35 normal) (Table 1). Present results show that there is variability in blood warfarin concentration in sensitive and normal patients, because sensitivity to warfarin is because of mutation in some genes like CYP2C9 and VKORC1 and the influence of these genes in individuals is different. Further work in our laboratory is going to determine the exact role of pharmacogenetic factors in warfarin sensitive Iranian patients in their CYP2C9 and VKORC1 genes.

Image for - Pharmacokinetic Analysis of Warfarin in Iranian Warfarin Sensitive Patients
Fig. 2: Chromatograms obtained with (A) blank blood, (B) blood spiked with warfarin (5 μg mL-1) (RT = 3.58), (C) patients` blood (RT = 3.95). The numbers above the peak are retention times (RT)

CONCLUSION


Present study developed a sensitive, reliable, rapid, cost-efficient and easy to perform HPLC method for assaying of warfarin in blood sample.

ACKNOWLEDGMENT


The authors wish to thank Imam Hospital for their grateful support of this work.

REFERENCES


  1. Andalibi, P., H. Farsam, M. Amanlou and M. Gharouni, 1998. Determination of dosage requirements of warfarin in Iranian patients using HPLC technique. J. Clin. Pharma. Ther., 23: 199-204.
    PubMed

  2. Ansell, J., J. Hirsh, J. Dalen, H. Bussey and D. Anderson et al., 2001. Managing oral anticoagulant therapy. Chest, 119: 22s-38s.
    PubMedDirect Link

  3. Cannegieter, S.C., F.R. Rosendaal, A.R. Wintzen, F.J.M. van der Meer, J.P. Vandenbroucke and E. Briet, 1995. Optimal oral anticoagulant therapy in patients with mechanical heart valves. N. Engl. J. Med., 333: 7-11.
    Direct Link

  4. Depr´e, M.A., M. Van Hecken, I. Oeyen, T. De Lepeleire and P. Laethem et al., 2005. Effect of aprepitant on the pharmacokinetics and pharmacodynamics of warfarin. Eur. J. Clin. Pharmacol., 61: 341-346.
    CrossRefPubMedDirect Link

  5. Hirsh, J., J.E. Dalen, D.R. Anderson, L. Poller and H. Bussey et al., 1998. Oral anticoagulants: Mechanisms of action, clinical effectiveness and optimal therapeutic range. Chest, 114: 445S-468S.
    PubMed

  6. Hirsh, J., J.E. Dalen, D.R. Anderson, L. Poller and H. Bussey et al., 2001. Minidose warfarin and failure to prevent deep vein thrombosis after joint replacement surgery despite inhibiting the postoperative rise in plasminogen activator inhibitor activity. Chest, 119: 8S-21S.

  7. Levine, M.N., G. Raskob, S. Landefeld and C. Kearon, 2001. Hemorrhagic complications of anticoagulant treatment. Chest, 119: 108S-121S.
    PubMedDirect Link

  8. Linder, M.W., 2001. Genetic mechanisms for hypersensitivity and resistance to the anticoagulant Warfarin. Clin. Chim. Acta, 308: 9-15.
    CrossRefPubMedDirect Link

  9. Lombardi, R., V. Chantarangkul, M. Cattaneo and A. Tripodi, 2003. Measurement of warfarin in plasma by high performance liquid chromatography (HPLC) and its correlation with the international normalized ratio. J. Thrombosis Res., 111: 281-284.
    CrossRef

  10. Modi, N.B., S. Kell, M. Simon and R. Vargas, 2005. Pharmacokinetics and pharmacodynamics of warfarin when coadministered with pentosan polysulfate sodium. J. Clin. Pharmacol., 45: 919-926.
    PubMedDirect Link

  11. Sconce, E.A., T.I. Khan, H.A. Wynne, P. Avery and L. Monkhouse et al., 2005. The impact of CYP2C9 and VKORC1 genetic polymorphism and patient characteristics upon warfarin dose requirements: Proposal for a new dosing regimen. Blood, 106: 2329-2333.
    CrossRefPubMedDirect Link

  12. Sun, S., M. Wang, L. Su, J. Li, H. Li and D. Gu, 2006. Study on warfarin plasma concentration and its correlation with international normalized ratio. J. Pharm. Biomed. Anal., 42: 218-222.
    CrossRefPubMedDirect Link

  13. Takahashi, H., G.R. Wilkinson, Y. Caraco, M. Muszkat and R.B. Kim et al., 2003. Population differences in S-warfarin metabolism between CYP2C9 genotype-matched Caucasian and Japanese patients. J. Clin. Pharmacol. Ther., 73: 253-263.
    CrossRefPubMedDirect Link

  14. Taube, J., D. Halsall and T. Baglin, 2000. Influence of cytochrome P-450 CYP2C9 polymorphisms on warfarin sensitivity and risk of over-anticoagulation in patients on long-term treatment. Blood, 96: 1816-1819.
    PubMedDirect Link

  15. Van der Meer, F.J.M., F.R. Rosendaal, J.P. Vandenbroucke and E. Briet, 1993. Bleeding complications in oral anticoagulant therapy. An analysis of risk factors. Arch. Int. Med., 153: 1557-1562.
    Direct Link

  16. Zhao, F., C. Loke, S. Rankin and J. Guo, 2004. Novel CYP2C9 genetic variants in Asian subjects and their influence on maintenance warfarin dose. Clin. Pharmacol. Ther., 76: 210-219.
    CrossRefPubMedDirect Link

Related Articles

Leave a Comment


Your email address will not be published. Required fields are marked *

Useful Links

  • Journals
  • For Authors
  • For Referees
  • For Librarian
  • For Socities

Contact Us

Office Number 1128,
Tamani Arts Building,
Business Bay,
Deira, Dubai, UAE

Phone: +971 507 888 742
Email: [email protected]

About Science Alert

Science Alert is a technology platform and service provider for scholarly publishers, helping them to publish and distribute their content online. We provide a range of services, including hosting, design, and digital marketing, as well as analytics and other tools to help publishers understand their audience and optimize their content. Science Alert works with a wide variety of publishers, including academic societies, universities, and commercial publishers.

Follow Us
© Copyright Science Alert. All Rights Reserved