ABSTRACT
An advanced computer controlled system for FES is developed that is aimed to give successful control to the electrical stimulation of muscle which is the time-varying nonlinear system. The performance of control systems is designed to be robust and can adapt to change in system gains. A DSP is programmed with Simulink for the study. In the circuit side, the new design of FES circuit is proposed that is connected together with the computer system. The circuit can give sufficient voltage without magnetic transformer that can also reduce significantly the circuit size and weight.
PDF References Citation
How to cite this article
K.W.E. Cheng, C.Y. Tang and C.P. Tsui, 2006. Development of Computer Controlled FES System with Improved Circuit Design. Journal of Applied Sciences, 6: 2438-2443.
DOI: 10.3923/jas.2006.2438.2443
URL: https://scialert.net/abstract/?doi=jas.2006.2438.2443
DOI: 10.3923/jas.2006.2438.2443
URL: https://scialert.net/abstract/?doi=jas.2006.2438.2443
REFERENCES
- Abbas, J.J. and H.J. Chiseck, 1991. Feedback control of plane hip angle in paraplegic subjects using functional neuromuscular stimulation. IEEE Trans. Biomed. Eng., 38: 687-698.
CrossRefDirect Link - Chizeck, H.J., P.E. Crago and L.S. Kofman, 1988. Robust closed-loop control of isometric muscle force using pulse width modulation. IEEE Trans. Biomed. Eng., 35: 510-517.
CrossRefDirect Link - Crago, P.E., R.J. Nakai and H.J. Chizeck, 1991. Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle. IEEE Trans. Biomed. Eng., 38: 17-28.
CrossRefDirect Link - Dariush, B., M. Pernianpour and H. Hemami, 1998. Stability and a control strategy of a multilink musculoskeletal model with applications in FES. IEEE Trans. Biomed. Eng., 45: 3-14.
CrossRefDirect Link - Qi, H., D.J. Tyler and D.M. Durand, 1999. Neurofuzzy adaptive controlling of selective stimulation for FES: A case study. IEEE Trans. Rehab. Eng., 7: 183-192.
CrossRefDirect Link - Tang, C.Y., B. Stojanovic, C.P. Tsui and M. Kojic, 2005. Modeling of muscle fatigue using hills model, biomed. Mater. Eng., 15: 341-348.
PubMed - Tsui, C.P., C.Y. Tang, C.P. Leung, K.W. Cheng, Y.F. Ng, D.H.K. Chow and C.K. Li, 2004. Active finite element analysis of skeletal muscle-tendon complex during isometric shortening and lengthening contraction. Bio-Med. Mater. Eng., 14: 271-279.
Direct Link - Watanabe, T., R. Futami, N. Hoshimiya and Y. Handa, 1999. An approach to a muscle model with a stimulus frequency-force relationship for FES applications. IEEE Trans. Rehab. Eng., 7: 12-18.
CrossRefDirect Link