<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article
  PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article" dtd-version="2.0" xml:lang="EN">

  <front>

    <journal-meta>

      <journal-title>Journal of Applied Sciences</journal-title>

      <issn pub-type="ppub">1812-5654</issn>

      <issn pub-type="epub">1812-5662</issn>

      <publisher>

        <publisher-name>Asian Network for Scientific Information</publisher-name>

      </publisher>

    </journal-meta>


    <article-meta>

      <article-id pub-id-type="doi">10.3923/jas.2007.1186.1190</article-id>


      <title-group>

        <article-title><![CDATA[Simulation Model of Brushless Excitation System]]></article-title>

      </title-group>


      <contrib-group>

        <contrib contrib-type="author" xlink:type="simple">


          <name name-style="western">

            <surname>N. Abdalla</surname>

            <given-names>Ahmed</given-names>

          </name>


          <name name-style="western">

            <surname>Anwar</surname>

            <given-names>Afaneen</given-names>

          </name>


        </contrib>

      </contrib-group>


      <pub-date pub-type="collection">


        <month>8</month>




        <year>2007</year>

      </pub-date>


      <volume>7</volume>

      <issue>8</issue>


      <abstract><![CDATA[<p>Excitation system is key element in the dynamic performance of electric power systems, accurate excitation models are of great importance in simulating and investigating the power system transient phenomena. Parameter identification of the Brushless excitation system was presented. First a block diagram for the EXS parameter was proposed based on the documents and maps in the power station. To identify the parameters of this model, a test procedure to obtain step response, was presented. Using the Genetic Algorithm with the Matlab-software it was possible to identify all the necessary parameters of the model. Using the same measured input signals the response from the standard model showed nearly the same behavior as the excitation system.</p>]]></abstract>


    </article-meta>

  </front>


  <ref-list>










      <ref id="5604">

        <label>1</label>

        <citation citation-type="conference" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Bhaskar, R., M.L. Crow, K. Erickson, K. Shah and R. Bhaskar,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>1998</year>

          <article-title><![CDATA[Excitation system nonlinear parameter estimation for power system stability studies: Feasibility study.]]></article-title>

          <source>Proceedings of the 30th North American Power Symposium,</source>

          <volume>1998</volume>

          <fpage>pp: 453</fpage>

          <lpage>458</lpage>

        </citation>

      </ref>


















      <ref id="5605">

        <label>2</label>

        <citation citation-type="conference" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Guo, T.Y., C.S. Liu and C.T. Huang,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>1993</year>

          <article-title><![CDATA[Identification of excitation system model parameters via finalization field tests.]]></article-title>

          <source>Proceedings of the 2nd International Conference on Advances in Power System Control, Operation and Management,</source>

          <volume>1993</volume>

          <fpage>pp: 833</fpage>

          <lpage>838</lpage>

        </citation>

      </ref>


















      <ref id="5606">

        <label>3</label>

        <citation citation-type="conference" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Liang, L.C., L.J. Zhen, N. Yuguang and Y. Wangye,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>2002</year>

          <article-title><![CDATA[The application of genetic algorithm in model identification.]]></article-title>

          <source>Proceedings of the Region 10th Conference on Computers, Communications, Control and Power Engineering,</source>

          <volume>2002</volume>

          <fpage>pp: 1261</fpage>

          <lpage>1264</lpage>

        </citation>

      </ref>














      <ref id="13994">

        <label>4</label>

        <citation citation-type="book" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Ljung, L.,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>1987</year>

          <article-title><![CDATA[System Identification, Theory for the User.]]></article-title>

          <source>System Identification, Theory for the User.</source>

          <volume></volume>

          <fpage></fpage>

          <lpage></lpage>

        </citation>

      </ref>






















      <ref id="5607">

        <label>5</label>

        <citation citation-type="conference" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Rasoli, M. and M. Karrari,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>2002</year>

          <article-title><![CDATA[Identification of brushless excitation system model parameters at different operting conditions via field tests.]]></article-title>

          <source>Proceedings of the 14th Power Systems Computation Conference,</source>

          <volume>2002</volume>

          <fpage>pp: 1</fpage>

          <lpage>2</lpage>

        </citation>

      </ref>












      <ref id="156750">

        <label>6</label>

        <citation citation-type="journal" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Rasouli, M. and M. Karrari,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>2004</year>

          <article-title><![CDATA[Nonlinear identification of a brushless excitation system via field tests.]]></article-title>

          <source>IEEE Trans. Energy Convers.,</source>

          <volume>19</volume>

          <fpage>733</fpage>

          <lpage>740</lpage>

        </citation>

      </ref>


















      <ref id="156752">

        <label>7</label>

        <citation citation-type="journal" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Rogers, G.,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>1996</year>

          <article-title><![CDATA[Demystifying power system oscillations.]]></article-title>

          <source>IEEE Comput. Applied Power,</source>

          <volume>9</volume>

          <fpage>30</fpage>

          <lpage>35</lpage>

        </citation>

      </ref>


















      <ref id="156756">

        <label>8</label>

        <citation citation-type="journal" xlink:type="simple">

          <person-group person-group-type="author">

            <name name-style="western">

              <surname>Zazo, A., J.L. Zamora, L. Rouco and F.L. Pagola,</surname>

              <given-names></given-names>

            </name>

          </person-group>

          <year>1994</year>

          <article-title><![CDATA[Identification of excitation systems from time response tests.]]></article-title>

          <source>Int. Conf. Control,</source>

          <volume>1</volume>

          <fpage>839</fpage>

          <lpage>843</lpage>

        </citation>

      </ref>
















  </ref-list>

</article>

