HOME JOURNALS CONTACT

Pakistan Journal of Biological Sciences

Year: 2003 | Volume: 6 | Issue: 8 | Page No.: 770-773
DOI: 10.3923/pjbs.2003.770.773
Flourogenic Assays for Rapid Detection of Escherichia coli in Tap Water and Raw Milk Samples
A. K. Azad, Fauzia Hafiz and S.M. Badiar Rahman

Abstract: As rapid microbiological reports of foods and food related products for E. coli bacteria presence are of prime importance. Rapid assays for E.coli were developed by using the compound 4-methyleumbelliferyl glucuronide (MUG), which is hydrolyzed by glucuronidase (GUD) to yield a fluorogenic product. The production of glucuronidase was limited to strains of E.coli in the family of Enterobacteriaceae. For rapid confirmation of the presence of E.coli in most probable number tubes (MPN), MUG was incorporated into lauryl tryptose broth at a final concentration of 100 μg ml-1. Results of both the presumptive test (gas formation) and the confirmed test (fluorescence) for E.coli were obtained from tap water and raw milk samples after incubation of 6-24 hours at 450C, Approximately 94% of the tubes showing both gas production and fluorescence contained fecal coliforms (they were positive in EC broth incubated at 450C). Few false positive reactions were observed. The lauryl tryptose broth MUG most probable numbers assay was superior to conventional study for E. coli detection. The fluorogenic assay was sensitive and rapid but conventional study was time consuming and laborious.

Fulltext PDF Fulltext HTML

How to cite this article
A. K. Azad, Fauzia Hafiz and S.M. Badiar Rahman, 2003. Flourogenic Assays for Rapid Detection of Escherichia coli in Tap Water and Raw Milk Samples. Pakistan Journal of Biological Sciences, 6: 770-773.

Keywords: Fluorescence, MUG and GUD and E. coli

Introduction

Coliform Fecal coliform or E. coli are considered the most important and compulsory measure of microbiological quality of food and food related products in terms of hygiene. Coliform, Fecal coliform or E.coli are all used as indicators of fecal pollution. Among these, E.coli is often preferred as an indicator because it is specific and most reliably reflects fecal origin. Conventional tests for coliforms and fecal coliforms or E.coli are time consuming in which require 5-6 days and deficiency in both precision and specificity. Therefore, has been placed on developing rapid tests for identifying E.coli as an indicator of direct or indirect fecal contamination in foods and food related products, The developments of rapid methods which are highly specific for identifying E.coli have been reviewed (Hofstra and huis in ‘t veld 1988; Hartman, 1 989). In this review, stress has been placed on the usefulness of a variety of methods used in E. coli assays based on detecting β-glucuronidase (GUD) activity. Although the bacterial enzyme was discover first in E.coli (Buchler et al., 1951). Its relative specificity for identifying this organism was not apparent until Kilian and Bulow (1976, 1979) surveyed the Enterobacteriaceae and the vibrionaceae and reported that GUD activity was mostly specific to E.coli.

In addition, the MPN assay is susceptible to bacterial interference (Allen et al., 1975; Geldreich et al., 1972; Anderson et al., 1980) false negative reactions (absence of gas production in the presence of coliforms) may occur at the presumptive, confirmed and completed steps of the MPN analysis (Evans and LeChevallier, 1981). Other factors, such as synergistic gas production from lactose by non-coliforms (Greer and Nyhan, 1928), cultivation of an aerogenic and non lactose fermenting E.coli strains (Anderson, Meadows, Mullins and Patel, 1980) and the presence of lactose fermenting non coliform (Hussong et al., 1980; Hussong et al., 1981), have contributed to the inefficiency of E.coli detection methodologies. The use of microbial enzyme profiles to detect indicator bacteria is an attractive alternative as existing method. Enzymatic reactions are specific, rapid and sensitive. For example, approximately 97% of the E.coli strain examined by (Kilian and Bulow, 1976) produced β-glucuronidase almost all other Enterobacteriaceae organisms lacked the enzyme GUD activities were initially detected with chromomeric substrates (Fishman, W.H., B. Springer, 1948); however a more sensitive assay with the fluorogenic compound 4-methyl umbelliferryl glucuronide has been used in recent years (Dahlen and Linde,1973; Maddocks et al., 1975; Mead et al., 1955). GUD cleaves MUG to release a fluorogenic end product that is visible under long wave (366 nm) UV light. The present study was under taken to developed rapid, specific and more efficient detection assays for E.coli by using the fluorogenic substrate MUG to detect GUD positive bacteria.

Materials and Methods

Specificity studies: The presence of GUD was determined by using a medium developed by Dahlen and Linde, 1973. To assay for GUD activity, growth from overnight cultures was stabbed into individual wells. The plate was incubated overnight at 37°C and examined for the appearance of fluorescence under long wave UV-light (Black light blue, Westinghouse [Bloomfield, N.J]; emission about 366nm) Because of their short wavelength, most germicidal lamps are not suitable for this purpose.

Application of MUG: The possibilities of using MUG directly in conventional coliform media were examined by using coliform detection methods. All media were prepared as specified by the manufactures. In the MPN method, MUG was incorporated into the presumptive medium. Appropriate concentrations of MUG were dissolved in distilled water and mixed with lauryl tryptose broth to obtain a final substrate concentration of 100 μg ml-1. The LST medium was then dispensed into tubes containing Durham vials and the tubes were sterilized in an autoclaved.

Analysis of contaminated samples: The efficiency of LST-MUG medium in the detection of E.coli was examined by using three tubes MPN method. Tap water samples were collected from many area in local city of Bangladesh. Water samples were three dilution (10, 1 and 0.1 ml) used to inoculate LST-MUG medium. Each assay was setup in triplicate (9 tubes per dilution) and incubated as specified previously (Anon, 1989). Presumptive counts of coliforms (gas production) and E.coli (fluorescence) were determined. The tubes that were gas positive [gas (+)], fluorescence positive [fluorescence (+)], or both were sub cultured into EC broth and incubated at 45°C to confirm the presence of fecal coliforms. A comparative fecal coliform count for each sample was also obtained by using standard conventional method (Anon.1989). Raw milk samples were collected from Dairy farm Each sample was analyzed in triplicate, by using the three tubes MPN assay with LST-MUG medium. Feng and Hartman (1982) developed the rapid assay method.

Identification of samples: Samples were identified based on their gross morphology and cultural characteristics along with biochemical reaction pattern. The biochemical tests were performed according to the method proposed by Edwards and Ewing(1986).

Results

The presence of GUD in E.coli bacteria was examined by UV light. The results were observed within 24 h. The E.coli colonies of LST-MUG medium show the bluish color (Fig. 1) when exposed to UV light at 366nm. 4-methylumbelliferone released by GUD activity diffused into the surrounding medium and eventually covered the entire area. On the studied of 88 tap water samples and 75 raw milk samples in which LST-MUG tubes that showed gas positive (76%), fluorescence positive (68%) and gas positive (87%), fluorescence positive (73%) respectively (Table 1).

Fig. 1:
The E. coli colonies of LST-MUG agar medium show the bluish color when exposed to UV light at 366 nm

Fig. 2:
The E. coli colonies of LST-MUG broth shows the bluish color of middle tube under long wave UV light

Table 1:Results of tap water and raw milk analysis by using the LST-MUG MPN method

Table 2:
Results of EC broth fecal coliform confirmatory tests on LST-MUG tubes obtained from MPN analysis of water and raw milk samples

Table 3:
Results of Comparative efficiency of the LST-MUG method versus conventional method for the detection of E.coli from MPN analysis

Table 4: Biochemical – physiological behavior of E. coli (Edwards and Ewing, 1986)

When MUG was incorporated into LST the presence of E.coli was detected by the appearance of fluorescence throughout the entire tube. E.coli produce gas in the tubes when inoculated into LST-MUG and shows bluish color under UV long wave of 366 nm confirming immediately that E.coli was present (Fig. 2).

Table 2 shows the results of EC broth fecal coliform confirmatory test on LST-MUG tubes obtained from MPN analysis by using tap water and milk samples. All tubes are subculture to EC broth and incubated at 45°C to check for the presence of fecal coliform or E.coli (fluorescence). In tap water samples where 88 tested samples showed gas positive fluorescence positive (94%) and also observed EC confirmatory tests were positive. But there also was a 7% apparent false positive reaction (production of gas in EC medium in the absence of fluorescence), 10-gas negative fluorescence positive tubes failed to produce gas in the EC confirmatory test (apparent false negative). In 75 raw milk samples, 59 of the gas (+) fluorescence (+) tubes obtained E.coli confirmed (91%) by EC broth. But there also was a 15% apparent false positive reaction (Production of gas in EC medium in absence of fluorescence positive tubes failed to produce gas in EC confirmatory test (apparent false negative).

Table 3 shows the results in comparative study of conventional and rapid method. Although the conventional method is time consuming but it is a standard method where the results varied 5-6% with rapid method and it is very low percentage in the aspect of microbial study of food and food related product.

The all tubes are identified from biochemical test for further confirmation of E.coli (Table 4).

Discussion

The presence of GUD in bacteria has been examined by several workers Kilian and Bulow (1979) tested 633 Enterobacteriaceae strains and reported that 97% of E.coli are positive for GUD reaction. The possibility of incorporating MUG directly in to conventional coliform assay was tested. This idea was appealing because the efficiencies of these methods have already been established. Furthermore, coliform media were commonly used, commercially produced and therefore readily available.

The LST-MUG media in an MPN assay, a presumptive coliform count could be obtained based on gas formation and immediate conformation for E.coli could be obtained based on fluorescence. Non-gas forming strains comprise about 5% of the E.coli population (Edwards and Ewing. 1972), and they’re a cause of false negative reaction in the presumptive confirmed, and even completed MPN analysis (Anderson, et al., 1980).

In rapid detection by incorporating MUG in coliform assays, E.coli may be detected immediately in one step procedures. Additional confirmatory test or biochemical reactions are not necessary, which means considerable savings in labor, time and media. Infect, if only an MPN for E.coli is desired. Durham tubes can be omitted from LST-MUG broth and the tubes can be examined only for fluorescence.

The analysis of tap water and raw milk samples showed that the fluoregenic LST-MUG MPN assay for E.coli was more efficient than the conventional method. The EC broth test for fecal coliforms confirmed that approximately 93% of the gas (+) fluorescence (+) tubes contained E.coli, and 7% apparently false positive reactions was observed. These results were not unusual because Geldreich (1966) reported that about 90% of E.coli and 8% of nonfecal coliforms produced gas in the EC broth test. The most interesting aspect, however, was that 13 gas (-) fluorescence (+) tubes failed to produce gas in EC broth confirmatory test.

REFERENCES

  • Allen, M.J. and E.E. Geldreich, 1975. Bacteriological criteria if ground water quality. Groundwater, 13: 1-7.


  • Anderson, J.G., P.S. Meadows, B.W. Mullins and K. Patel, 1980. Gas production of Escherichia coli in selective lactose fermentation media. FEMS Microbiol. Lett., 8: 17-21.


  • Anonymous, 1989. Standard Methods for the Examination of Water and Wastewater. 17th Edn., American Public Health Association (APHA), Washington, DC


  • Buchler, H.J., P.A. Katzman and E.A. Doisy, 1951. Studies on β-glucuronidase from E. coli.Studies on β-glucuronidase from E. coli. Proc. Soc. Exp. Biol. Med., 76: 672-676.


  • Dahlen, G. and A. Linde, 1973. Screening plate methods for detection of bacterial β-glucuronidase. Applied Microbiol., 26: 863-866.


  • Edwards, P.R. and W.H. Ewing, 1972. Identification of Enterobacteriaceae. 3rd Edn., Burgess Publishing Co., Minneapolis


  • Evans, T.M., M.W. LeChevallier, C.E. Waarvick and R.J. Seidler, 1981. Coliform species recovered from untreated surface water and drinking water by membrane filter, standard and modified MPN techniques. Applied Environ. Microbiol., 41: 657-663.


  • Edwards, P.R. and W.H. Ewing, 1986. Edwards and Ewing's Identification of Enterobacteriaceae. 4th Edn., Elsevier's Science, New York


  • Feng, P.C.S. and P.A. Hartman, 1982. Fluoregenic assays for immediate confirmation of Escherichia coli. Applied Environ. Microbiol., 43: 1320-1329.


  • Fishman, W.H., B. springer and R. Burnett, 1948. Application of an improved glucuronidase assay method to the study of human blood. J. Biol. Chem., 173: 449-455.


  • Geldreich, E.E., 1966. Sanitary significance of fecal coliforms in the environment. Water Pollution Research Publication No. WP-20-3. US Department of the Interer. Washington, DC.


  • Geldreich, E.E., H.D. Nash, D.J. Reasoner and R.H. Tailor, 1972. The necessity of controlling bacterial population in potable water: Community water supply. J. Am. Water Works Assoc., 64: 596-602.


  • Greer, F.E. and F.V. Nyhan, 1928. The sanitary significance of lactose fermenting organisms not belonging to the E. coli group. 3. Bacterial association in culture containing lactose-fermenting bacteria. J. Infect. Dis., 42: 525-536.


  • Hofstra, H. and J.H.J. Huis, 1988. Methods for the detection and isolation of Escherichia coli including pathogenic strains. J. Applied Bacteriol. Symp. Suppl., 65: 197-212.


  • Hussong, D., R.R. Colwell and R.M. Weiner, 1980. Rate of occurrence of false positive results from total coliform most probable number analysis of shellfish and estuaries. Applied Environ. Microbiol., 40: 981-983.


  • Hussong, D., J.M. Damare, R.M. Weiner and R.R. Colwell, 1981. Bacteria associated with false positive most probable number coliform test results for shellfish estuaries. Applied Environ. Microbiol., 41: 35-45.


  • Kilian, M. and P. Bulow, 1976. Rapid diagnosis of enterobacteriaceae I. Detection bacterial glycosidase. Acta Pathol. Microbiol. Scandinavica Section B, 84: 245-251.


  • Kilian, M. and P. Bulow, 1979. Rapid identification of Enterobacteriaceae II. Use of β-glucuronidase detecting agar medium (PGUA) for the identification of E. coli in primary cultures of urine samples. Acta Pathol. Microbiol. Scandinavica Section B., 87: 271-276.


  • Maddocks, J.L. and M.J. Greenan, 1975. A rapid method for identifying bacterial enzymes. J. Clin. Pathol., 28: 686-687.


  • Mead, J.A.R., J.N. Smith and R.T. Williams, 1955. The biosynthesis of the glucuronides of umbelliferone and 4-methylumbelliferone and their use in fluorimetric determination of β-glucuronidase. J. Biochem., 61: 569-574.


  • Hartman, P., 1989. The MUG Test for E. coli in Food and Water. In: Rapid Methods and Automation in Microbiology and Immunology, Ballows, A., R.C. Tilton and A. Turano (Eds.). Brixia Academic Press, Brescia, Italy

  • © Science Alert. All Rights Reserved