Influence of the Prosthetic Parameters on the Durability of the Material Couple Constituent: The Link of a Femoral Prostheses of Hip
Abstract:
The constant evolution of an artificial hip tries to put in presence of new articular surfaces perfectly spherical, susceptible to articulate in a prolonged way with reduced liberation of wear debris. The effect of the prosthetic parameters on the durability of the material couple used in the joint ball of the femoral side and cupule of the cotyledon side is studied. The distribution of the contact pressure has been calculated while introducing the three components of the load applied on the femoral head of the hip creating three components of the movement that have been respectively considered for the calculation of slippery distance. The analyses show that the volume of wear increases with the patient weight and the roughness of the articular surfaces. It increases up to a maximum with increasing of the femoral diameter and the modulus of elasticity then it decreases and stabilizes in an asymptotic manner.
How to cite this article
D. Ouinas, B.B. Bouiadjra, B. Serier and A. Ouinas, 2007. Influence of the Prosthetic Parameters on the Durability of the Material Couple Constituent: The Link of a Femoral Prostheses of Hip. Journal of Applied Sciences, 7: 2385-2388.
REFERENCES
Archard, J.F., 1953. Contact and rubbing of flat surface. J. Applied Phys., 24: 981-988.
Bertei, D.L., A.H. Burstein, M.D. Toda and D.L. Edwards, 1985. The effect of conformity and plastic thickness on contact stress in metal-backed plastic implants. J. Biomech. Eng., 107: 193-199.
Bergmann, G., F. Graichen and A. Rohlmann, 1993. Hip joint loading during walking and running, measured in two patients. J. Biomachanics, 26: 969-990.
Del Schutte, H.J., A.J. Lipman, S.M. Bannar, J.T. Livarmore, D. Ilstrup and B.F. Morrey, 1998. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J. Arthrol., 13: 621-626.
PubMed Direct Link
Gomez-Barrena, E., S. Li, B.A. Masri, T.M. Wright and E.A. Salvati, 1998. Role of polyethylene oxidation and consolidation defects in cup performance. Clin. Orthop., 352: 105-117.
PubMed Direct Link
Hali, R.M., P. Siney, A. Unsworth and B.M. Wroblrwski, 1998. The association between rates of wear in retrieved acetabular components and the radius of the femoral head. Part H. J. Eng. Med., 212: 321-326.
PubMed Direct Link
Harris, W.H., 1995. The problem is osteolysis. Clin. Orthop., 311: 46-53.
Direct Link
Hoeltzei, D.A., M.J. Walt, R.F. Kyle and F.D. Simon, 1989. The effects of femoral head size on the deformation of ultrahigh molecular weight Polyethylene acetabular cups. J. Biomechanics, 22: 1163-1173.
Jin, Z.M., D. Dowson and J.A. Fisher, 1994. Parametric analysis of the contact stress in ultrahigh molecular weight Polyethylene acetabular cups. Med. Eng. Phys., 16: 398-405.
Maxian, T.A., T.D. Brown, D.R. Pedresen and J.J. Callaghan, 1996. A sliding distance-coupled finite elements formulation for polyethylene wear in total hip arthroplasty. J. Biomechanics, 29: 687-692.
PubMed Direct Link
Maxian, T.A., T.D. Brown, D.R. Pedresen, H.A. McKellop, B. LU and Callaghan, 1997. Finite element analysis of acetabular wear: Validation and backing and fixation effects. Clin. Orthop., 344: 111-117.
PubMed Direct Link
McGee, M.A., D.W. Howie, S.D. Neale, D.R. Haynes and M.J. Pearcy, 1997. The role of polyethylene wear in joint failure. Proc. Instn. Mech. Engrs, Part H. J. Eng. Med., 211: 65-72.
PubMed Direct Link
Raimondi, M.T., C. Santambrogio, R. Piertrabissa, F. Raffelini and L. Molfetta, 2001. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components. Proc. Instn. Mech. Eng., 215: 377-391.
Direct Link
Seedom, B.B. and N.C. Wallbridge, 1985. Walking activities and wear of prosthess. Ann. Rheum. Dis., 44: 838-843.
Sutherland, D.H., R. Olshen, L. Cooper and S.L. Woo, 1980. The development of mature gait. J. Bone It Surg. Am, 62: 336-353.
Wang, A., V.K. Polineni, C. Stark and J.H. Dumbleton, 1998. Effect of femoral head surface roughness on the wear of ultrahigh molecular weight Polyethylene acetabular cups. J. Arthro., 13: 615-620.
PubMed Direct Link
Whitehouse, D.J., 1994. Surface geometry and its importance in function: Handbook of Surface Metrology. Institute of Physics Publishing, Bristol, pp: 749-759
© Science Alert. All Rights Reserved