Influence of the Prosthetic Parameters on the Durability of the Material Couple Constituent: The Link of a Femoral Prostheses of Hip
D. Ouinas, B.B. Bouiadjra, B. Serier and A. Ouinas

Abstract: The constant evolution of an artificial hip tries to put in presence of new articular surfaces perfectly spherical, susceptible to articulate in a prolonged way with reduced liberation of wear debris. The effect of the prosthetic parameters on the durability of the material couple used in the joint ball of the femoral side and cupule of the cotyledon side is studied. The distribution of the contact pressure has been calculated while introducing the three components of the load applied on the femoral head of the hip creating three components of the movement that have been respectively considered for the calculation of slippery distance. The analyses show that the volume of wear increases with the patient weight and the roughness of the articular surfaces. It increases up to a maximum with increasing of the femoral diameter and the modulus of elasticity then it decreases and stabilizes in an asymptotic manner.

Fulltext PDF

How to cite this article
D. Ouinas, B.B. Bouiadjra, B. Serier and A. Ouinas, 2007. Influence of the Prosthetic Parameters on the Durability of the Material Couple Constituent: The Link of a Femoral Prostheses of Hip. Journal of Applied Sciences, 7: 2385-2388.

Keywords: Wear volume, total hip arthroplasty and mathematical modeling

REFERENCES

  • Archard, J.F., 1953. Contact and rubbing of flat surface. J. Applied Phys., 24: 981-988.


  • Bertei, D.L., A.H. Burstein, M.D. Toda and D.L. Edwards, 1985. The effect of conformity and plastic thickness on contact stress in metal-backed plastic implants. J. Biomech. Eng., 107: 193-199.


  • Bergmann, G., F. Graichen and A. Rohlmann, 1993. Hip joint loading during walking and running, measured in two patients. J. Biomachanics, 26: 969-990.


  • Del Schutte, H.J., A.J. Lipman, S.M. Bannar, J.T. Livarmore, D. Ilstrup and B.F. Morrey, 1998. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J. Arthrol., 13: 621-626.
    PubMed    Direct Link    


  • Gomez-Barrena, E., S. Li, B.A. Masri, T.M. Wright and E.A. Salvati, 1998. Role of polyethylene oxidation and consolidation defects in cup performance. Clin. Orthop., 352: 105-117.
    PubMed    Direct Link    


  • Hali, R.M., P. Siney, A. Unsworth and B.M. Wroblrwski, 1998. The association between rates of wear in retrieved acetabular components and the radius of the femoral head. Part H. J. Eng. Med., 212: 321-326.
    PubMed    Direct Link    


  • Harris, W.H., 1995. The problem is osteolysis. Clin. Orthop., 311: 46-53.
    Direct Link    


  • Hoeltzei, D.A., M.J. Walt, R.F. Kyle and F.D. Simon, 1989. The effects of femoral head size on the deformation of ultrahigh molecular weight Polyethylene acetabular cups. J. Biomechanics, 22: 1163-1173.


  • Jin, Z.M., D. Dowson and J.A. Fisher, 1994. Parametric analysis of the contact stress in ultrahigh molecular weight Polyethylene acetabular cups. Med. Eng. Phys., 16: 398-405.


  • Maxian, T.A., T.D. Brown, D.R. Pedresen and J.J. Callaghan, 1996. A sliding distance-coupled finite elements formulation for polyethylene wear in total hip arthroplasty. J. Biomechanics, 29: 687-692.
    PubMed    Direct Link    


  • Maxian, T.A., T.D. Brown, D.R. Pedresen, H.A. McKellop, B. LU and Callaghan, 1997. Finite element analysis of acetabular wear: Validation and backing and fixation effects. Clin. Orthop., 344: 111-117.
    PubMed    Direct Link    


  • McGee, M.A., D.W. Howie, S.D. Neale, D.R. Haynes and M.J. Pearcy, 1997. The role of polyethylene wear in joint failure. Proc. Instn. Mech. Engrs, Part H. J. Eng. Med., 211: 65-72.
    PubMed    Direct Link    


  • Raimondi, M.T., C. Santambrogio, R. Piertrabissa, F. Raffelini and L. Molfetta, 2001. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components. Proc. Instn. Mech. Eng., 215: 377-391.
    Direct Link    


  • Seedom, B.B. and N.C. Wallbridge, 1985. Walking activities and wear of prosthess. Ann. Rheum. Dis., 44: 838-843.


  • Sutherland, D.H., R. Olshen, L. Cooper and S.L. Woo, 1980. The development of mature gait. J. Bone It Surg. Am, 62: 336-353.


  • Wang, A., V.K. Polineni, C. Stark and J.H. Dumbleton, 1998. Effect of femoral head surface roughness on the wear of ultrahigh molecular weight Polyethylene acetabular cups. J. Arthro., 13: 615-620.
    PubMed    Direct Link    


  • Whitehouse, D.J., 1994. Surface geometry and its importance in function: Handbook of Surface Metrology. Institute of Physics Publishing, Bristol, pp: 749-759

  • © Science Alert. All Rights Reserved