Background and Objective: Several research studies have found a relationship between exposure to indoor particulates and serious health problems. In this research, the mass concentration of inhalable particles in four offices is measured experimentally. Materials and Methods: Three airborne particles sizes (PM1, PM2.5 and PM10), were monitored in the offices during occupancy and non-occupancy periods, Qassim University Campus, KSA. Results: The results show that most activities made in the investigated offices are a strong factor affecting PM10 and PM2.5. However, the influence of such activities on PM1 was not strong except for vacuuming where the concentration level increased during cleaning activity. The impact of outdoor particles on the air inside was significant for PM1 and PM2.5, while its effect on PM10 was moderate. Conclusion: Particulates generated outdoor contributed significantly to the particle concentrations in the offices, particularly for PM1 and PM2.5 size fractions. The concentration level of the particle fractions (PM10 and PM2.5) during the occupancy period does not satisfy the World Health Organization (WHO).

Services
Related Articles in ASCI
Search in Google Scholar
View Citation
Report Citation

 
  How to cite this article:

Abdulaziz B. Alharbi , 2021. Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition. Research Journal of Environmental Sciences, 15: 1-8.

DOI: 10.3923/rjes.2021.1.8

URL: https://scialert.net/abstract/?doi=rjes.2021.1.8
 

INTRODUCTION

Several studies have reported that exposure to indoor and outdoor airborne particles are associated with health problems1-3. In particular, particulates with small sizes (e.g. PM1 and PM2.5) are known to have a bigger health effect4-7. These sizes can reach deeper portions of the respiratory tract8,9. Other previous studies have also considered the risk resulting from short-term exposure to airborne pollutants10-12. It has been documented that exposure to a concentration of 200 μg m-3 of fine particles for 2 hrs could cause serious health problems to the respiratory system13,14.

Lack of sufficient fresh air increases the concentration of indoor particulate matter15. Therefore, failure to improve the quality of indoor air could influence human health, especially among the elderly, people with heart and/or lung diseases, children and women16,17. It is referred to as the Sick Building Syndrome (SBS) and this has recently been given attention to limit the health risk related to insufficient fresh air.

Although people spend between 10-15% only of their time outdoors, the majority of time is spent indoors. Many studies have given attention to the concentration of outdoor particulate matter18-21. However indoor studies are relatively new while indoor particulate concentrations are often higher than outdoor concentrations22,23. Thus, recently, much consideration has been invested in examining air quality in different indoor environments24-29.

Generally, airborne indoor particle concentrations are considered to be dependent on the outdoor particulate matter30. The paths of transporting ambient particles into indoor areas are via indoor openings (e.g., windows and doors), cracks and ventilation systems. However, several human activities take place in indoor environments such as walking, cooking, dusting, vacuuming, smoking that result in elevated particulate matter concentrations31-33. Therefore, exposure to particulate matter in indoor air can change rapidly due to the rapid changes in occupant activities and sources34.

Previous studies have reported that poor quality environments in offices decrease productivity35,36, thus increasing productivity could be achieved by improving office environmental parameters37. The study carried out by Ponsoni and Raddi38 showed a positive correlation between occupancy and airborne bacteria in a public office building.

Poor building ventilation and indoor air contaminants increased health conditions among workers in office rooms39. Mendell et al.40 reported that building-related symptoms in the United States could increase the annual loss of productivity (from 7-75$ billion/year). Particles suspended in room air could be responsible for discomfort and health problems to office workers and their concentration is changing rapidly41. A previous study conducted by Molhave42 documented that 5 hrs of exposure to office dust could influence healthy people. The sources which increase the concentration levels of airborne particulates in office rooms vary. Besides, they could emit pollutants that are more hazardous compared to those in the ambient air. Several research studies have investigated the impact of office devices (e.g., printers, photocopiers, etc.) on the concentration of particulate matter in office microenvironments43,44. The results showed that those devices are important sources for an airborne particle in the size range <0.1 μm.

There is an important knowledge gap in the airborne indoor particle concentrations in Saudi Arabia. Therefore, investigating different particle size classes in different indoor environments could be very important for indoor personal exposure studies in Saudi Arabia. This study reported data on the diurnal variations of airborne mass concentrations for different particulates including PM1, PM2.5 and PM10 in several offices at the Qassim University Campus, KSA. The concentration levels of such fractions during occupancy and non-occupancy periods were investigated. Besides, the impact of outdoor pollutants on the concentrations of airborne particles in the offices was studied.

MATERIALS AND METHODS

Study area: Particulate matter mass concentrations of PM1, PM2.5 and PM10 were monitored for 5 months (September, 2018-February, 2019) at Qassim University Campus, KSA. Four offices were investigated. The offices selected were listed in Table 1.

Methodology: Particulate matter fractions in the offices and outdoors were monitored using two units of Grimm Portable Laser Aerosol Spectrometer model 1.108 (GRIMM Aerosol Technik, Ainring GmbH and Co. KG, Germany). This device uses a light-scattering technique for measuring particle concentration and gives real-time measurements of different particle size ranges. The air sampled was continuously drawn into the instrument by a pump with a flow rate of 0.0012 m3 min–1.

Table 1:
Demonstrate the specification of the office rooms selected for the study*
Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition
*All offices are ventilated during working hours (5.00 am-17.00 pm) by a central ventilation system

Measurements of airborne particle mass concentrations at the Qassim University Campus, KSA were made during weekdays (daytime and night). The purpose of the daytime and night measurements was to assess the impact of occupant’s related activities and the impact of outdoor particles on the Particulate Matter (PM) in the offices respectively. The particle monitoring units were set to simultaneously measure PM1, PM2.5 and PM10 fractions (particles with an aerodynamic diameter equal or less than 1, 2.5 and 10 μm, respectively) in the selected offices. Work time is usually from 08:00 am-2:30 pm and the measurements cover the occupied and unoccupied periods. The optical particle sampler was placed in the middle of the offices at a height of 1.30 m above floor level, which represents the breathing level of a sedentary seated adult of average height. The measuring unit was set to a 1 min data logging interval (each reading was an average of 1 min) because with such short intervals activities showed a clear influence on the indoor concentration, but for longer intervals, this effect could not be captured. Outdoor measurement of airborne PM mass concentrations was conducted simultaneously.

RESULTS AND DISCUSSION

The data of Table 2 shows the dates of the sampling periods for the particulate matter fractions measured in the office rooms and average daily airborne particle mass concentration levels. It can be noted from the table that the average daily PM is not consistent, particularly for larger particles (e.g., PM10 in the director (D) and secretary (S1) offices). The average mass concentration for PM10 ranges between 8.70-47.65 and 12.83-52.31 μg m–3 for D and S1 offices respectively. While PM1 and PM 2.5 the average ranges between 3.96-8.70 and 5.12-13.46 μg m–3, respectively for office D. For office S1, the average of PM1 and PM2.5 ranges between 6.52-9.36 and 7.98-14.52 μg m–3, respectively. On the other hand, the average daily particulate matter concentrations for office S2 and office M is not significantly varied for most of the particle fractions monitored.

To understand the variation of the average daily particulate matter mass concentration in the office rooms, the measurement campaigns were divided into two different periods. One period represented sampling during working hours (daytime; 8:00 am-3:30 pm) and the other one represented sampling during night time (8:00 pm-5:00 am). The data of Table 3 illustrates the concentration of different particulate fractions during daytime and nighttime monitoring periods. From the table, it is clear that daytime samplings have higher particle mass concentrations than night time for most of the particle fractions measured. This suggested that the particle concentrations in the offices could be influenced by activities that took place in these rooms during working hours.

Particle mass concentrations for PM1, PM2.5 and PM10 during working hours for occupied and unoccupied offices are shown in Table 4.

Table 2:
Dates of the sampling measurements and average daily particle mass concentration monitored in the office rooms
Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition

Table 3:
Average ranges of particle mass concentration (μg m–3) monitored in the office rooms during the day and night periods
Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition

Table 4:Average mass concentrations (μg m–3) for different particle fractions during occupied and unoccupied periods in the selected offices
Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition

Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition
Fig. 1(a-c): Variations in particulate fractions for a typical day of measurement in the director's office (D) during occupancy
  (a) PM1, (b) PM2.5 and (c) PM10 concentration

It can be seen that during occupancy samplings particles concentration levels are higher than those during unoccupied periods for the majority of the monitoring campaigns and human-related activities (e.g., walking around, vacuuming, etc.) the only factor that could be suggested to explain the increasing particulate mass levels during such periods (e.g., occupied periods). When the employees occupied the offices, resuspension of particles larger than 1 μm is significant, which leads to higher levels than those when they were not attended. This finding is consistent with previous findings in other situations. A previous study was carried out in three different indoor environments (e.g., office, café and home) reported that particle concentration increased when the indoor environments were occupied due to resuspension from people's movement and other activities indoor that emitted particles such as cooking34. Another investigation carried out in a house reported that human activity increased the concentration levels of particles with an aerodynamic diameter equal or less than 10 μm45. On the other hand, in general, the effect of occupancy periods on the small fraction (e.g., PM1) in this study is insignificant. This result agrees well with the results shown by a previous study conducted in classrooms28.

The influence of human-related activities on the concentrations of particles in offices during working hours is demonstrated in Fig. 1a-b. The figure shows sampling measurements that were taken in office D on day 4/12/2018. It should be noted that the office was occupied by one employee (e.g., the director) and on some occasions, one or two persons enter the office to meet the director. The activities recorded on that day were several people entering and leaving the office (movement levels) and vacuuming. Concerning the small fraction (e.g., PM1), see Fig. 1a, the spectrum of the particle concentration was slightly different than those for PM2.5 and PM10. The effect of level of movement was insignificant for PM1. Whereas, the impact of vacuuming on PM1 fraction concentration was significant and gave a similar trend to observed in PM2.5 and PM10 (e.g., the period between 11:10 am and 11:20 am). This suggested that vacuuming emitted fine particles (<1 μm).

It is clear from the figure that larger particulates (e.g. PM2.5 and PM10) show a similar trend which suggested that both size fractions were influenced by the activities made in the office (people movements and vacuuming).

Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition
Fig. 2(a-c): Secretary office (S1) and outdoor PM concentrations (date of measurements; 13/2/2019-14/2/2019)
  (a) PM1, (b) PM2.5 and (c) PM10 concentration

Looking at the concentration profiles of PM2.5 and PM10 (Fig. 1b-c), high concentration levels were observed which are related to high activities. For example, high concentration levels at the beginning of the measurements (10:00 am) were thought to be partly due to the presence of two persons before 10:00 am to install the instrumentation before the start of samplings which caused a high level of movement. The concentrations started to decay after finishing the installation due to low activity levels. However, several small peaks were found (e.g., at 10:30, 10:55 am and 12:00 pm) which were related to a person (visitor) entered the office (low level of movement). When the visitor was seated, the movement stopped and the decay started. The particle concentrations rapidly rose during the period between 11:10 and 11:20 am and vacuuming was the only factor recognized to describe the increasing particle fraction concentration levels.

The result of Fig. 2a-c shows the concentration profiles of the three-particle fractions (PM1, PM2.5 and PM10) during the sampling campaigns in the secretary office (S1) and outdoor. The purpose of this measurement was to study the impact of outdoor particles on the concentration levels of particulate in the office air. To investigate this impact the concentration levels in S1 were obtained from the measurements carried out during unoccupied periods to avoid the influence of any indoor activities on such investigation. It is clear from the figure that PM1 and PM2.5 followed the concentration spectrum of outdoor suggesting that both fractions were influenced by outdoor concentrations (Fig. 2a-b). On the other hand, PM10 seems to be independent of the particle concentrations outdoor (Fig. 2c). this result agrees with another study in Poland concluded that there significant correlations between indoor and outdoor PM concentrations46.

A simple linear correlation was employed to determine the correlation between the concentration levels inside and outside. The result of Fig. 3a-b illustrates the relationship between the Secretary Office (S1) and outdoor particle fractions. There was an influence of outdoor concentrations, particularly for fine fractions (PM1 and PM2.5). The correlation between indoor airborne particles and those found outdoor is much stronger, particularly for PM1 and PM2.5 (R2 = 0.91 and 0.85, respectively), see Fig. 3a-b. A relatively good correlation was determined for indoor and outdoor PM10 concentrations (R2 = 0.55), see Fig. 3c. In our study only mechanical ventilation was used. In general, the correlation is stronger when the outdoor concentration varies (increasing or decreasing), a sufficient air change between indoor and outdoor exists and during the absence of indoor sources. This examination was able to show a strong positive correlation between the outdoor fine fractions levels and those in the offices recorded.

This suggested that small particles are influenced strongly by outdoor ones but large particles are affected strongly by human activity. It has previously been found that indoor fine particles are well correlated with ambient concentrations because they have higher penetration efficiency than larger ones47,48. The concentration levels of the particle indoor were higher than the World Health Organization (WHO) standard for annual average which has been set at 20 μg m–3 for PM10 and 10 μg m–3 for PM2.514. The impact of outdoor particle concentrations on the air quality indoor must be taken into account when designing buildings in dry areas, as well as reducing the impact of various activities on indoor air quality.

Image for - Evaluation of the Relationship Between Outdoor Environment and Indoor Air Quality in Arid Condition
Fig. 3(a-c): Secretary office (S1) and outdoor PM concentrations relationship with an unoccupied period
  (a) PM1, (b) PM2.5 and (c) PM10 concentration

CONCLUSION

The results obtained from the monitoring instruments showed that the most significant parameters for generating particles in the offices were human-related activities. Walking generated substantial amounts of larger particulates (e.g., PM10). Particulates generated outdoor contributed significantly to the particle concentrations in the offices, particularly for PM1 and PM2.5 size fractions. The concentration levels of the particle fractions (PM10 and PM2.5) during the occupancy period do not satisfy the World Health Organization.

SIGNIFICANCE STATEMENT

This study discovered the diurnal variations of airborne mass concentrations for different particulates including PM1, PM2.5 and PM10 by high precision technic using Grimm Portable Laser Aerosol Spectrometer was to assess the impact of occupants related activities and the impact of outdoor particles on the particulate matter in indoor. This study will help the researchers to uncover the critical areas of environmental change especially in an arid land that many researchers were not able to explore.

ACKNOWLEDGMENT

The author wishes to thank Qassim University for their help in providing the opportunity to conduct experiments on its campus.

REFERENCES

1:  Davidson, C.I., R.F. Phalen and P.A. Solomon, 2005. Airborne particulate matter and human health: A review. Aerosol Sci. Technol., 39: 737-749.
CrossRef  |  Direct Link  |  

2:  Pope, C.A. and D.W. Dockery, 2006. Health effects of fine particulate air pollution: Lines that connect. J. Air Waste Manage. Assoc., 56: 709-742.
CrossRef  |  PubMed  |  Direct Link  |  

3:  Landrigan, P.J., R. Fuller, N.J.R. Acosta, O. Adeyi and R. Arnold et al., 2018. The Lancet commission on pollution and health. Lancet, 391: 462-512.
CrossRef  |  PubMed  |  Direct Link  |  

4:  Owen, M.K., D.S. Ensor and L.E. Sparks, 1992. Airborne particle sizes and sources found in indoor air. Atmos. Environ. Part A. Gen. Top., 26: 2149 -2162.
CrossRef  |  Direct Link  |  

5:  Schwartz, J. and L.M. Neas, 2000. Fine particles are more strongly associated than coarse particles with acute respiratory health effects in schoolchildren. Epidemiology, 11: 6-10.
CrossRef  |  Direct Link  |  

6:  Franck, U., O. Herbarth, S. Röder, U. Schlink and M. Borte et al., 2011. Respiratory effects of indoor particles in young children are size dependent. Sci. Total Environ., 409: 1621-1631.
CrossRef  |  Direct Link  |  

7:  Zhang, R., G. Wang, S. Guo, M.L. Zamora and Q. Ying et al., 2015. Formation of urban fine particulate matter. Chem. Rev., 115: 3803-3855.
CrossRef  |  Direct Link  |  

8:  Berico, M., A. Luciani and M. Formignani, 1997. Atmospheric aerosol in an urban area: Measurements of TSP and PM10 standards and pulmonary deposition assessments. Atmos. Environ., 31: 3659-3665.
CrossRef  |  Direct Link  |  

9:  Buoli, M., S. Grassi, A. Caldiroli, G.S. Carnevali and F. Mucci et al., 2018. Is there a link between air pollution and mental disorders? Environ. Int., 118: 154-168.
CrossRef  |  Direct Link  |  

10:  Delfino, R.J., R.S. Zeiger, J.M. Seltzer and D.H. Street, 1998. Symptoms in pediatric asthmatics and air pollution: Differences in effects by symptom severity, anti-inflammatory medication use and particulate averaging time. Environ. Health Perspect., 106: 751-761.
CrossRef  |  Direct Link  |  

11:  Gold, D.R., A. Litonjua, J. Schwartz, E. Lovett and A. Larson et al., 2000. Ambient pollution and heart rate variability. Circulation, 101: 1267-1273.
CrossRef  |  Direct Link  |  

12:  Linares, C. and J. Díaz, 2010. Short-term effect of concentrations of fine particulate matter on hospital admissions due to cardiovascular and respiratory causes among the over-75 age group in Madrid, Spain. Pub. Health, 124: 28-36.
CrossRef  |  Direct Link  |  

13:  WHO, 2006. Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide Global update 2005: Summary of risk assessment WHO/SDE/PHE/OEH/06.02. Geneva, Switzerland. https://apps.who.int/iris/handle/10665/69477

14:  World Health Organization, 2016. WHO expert consultation: Available evidence for the future update of the WHO global air quality guidelines (AQGs). WHO: Geneva, Switzerland. http://www.euro.who.int/__data/assets/pdf_file/0013/301720/Evidence-future-update-AQGs-mtg-report-Bonn-sept-oct-15.pdf

15:  Turiel, I., C.D. Hollowell, R.R. Miksch, J.V. Rudy, R.A. Young and M.J. Coye, 1983. The effects of reduced ventilation on indoor air quality in an office building. Atmos. Environ. (1967), 17: 51-64.
CrossRef  |  Direct Link  |  

16:  Kim, K.H., E. Kabir and S. Kabir, 2015. A review on the human health impact of airborne particulate matter. Environ. Int., 74: 136-143.
CrossRef  |  Direct Link  |  

17:  Liang, R., B. Zhang, X. Zhao, Y. Ruan, H. Lian and Z. Fan, 2014. Effect of exposure to PM2. 5 on blood pressure: A systematic review and meta-analysis. J. Hypertens., 32: 2130-2141.
CrossRef  |  Direct Link  |  

18:  Jenkins, P.L., T.J. Phillips, J.M. Mulberg and S.P. Hui, 1992. Activity patterns of californiansuse of and proximity to indoor pollutant sources. Atmos. Environ., 26: 2141-2148.
Direct Link  |  

19:  Dockery, D.W., C.A. Pope, X. Xu, J.D. Spengler and J.H. Were et al., 1993. An association between air pollution and mortality in six U.S. cities. New Eng. J. Med., 329: 1753-1759.
CrossRef  |  Direct Link  |  

20:  Schwartz, J., D.W. Dockery and L.M. Neas, 1996. Is daily mortality associated specifically with fine particles? J. Air Waste Manage. Assoc., 46: 927-939.
CrossRef  |  Direct Link  |  

21:  Chock, D.P., S.L. Winkler and C. Chen, 2000. A study of the association between daily mortality and ambient air pollutant concentrations in pittsburgh, pennsylvania. J. Air Waste Manage. Assoc., 50: 1481-1500.
CrossRef  |  Direct Link  |  

22:  Wallace, L., 1996. Indoor particles: A review. J. Air Waste Manage. Assoc., 46: 98-126.
CrossRef  |  Direct Link  |  

23:  Monn, C., 2001. Exposure assessment of air pollutants: A review on spatial heterogeneity and indoor/outdoor/personal exposure to suspended particulate matter, nitrogen dioxide and ozone. Atmos. Environ., 35: 1-32.
CrossRef  |  Direct Link  |  

24:  Wang, X., X. Bi, G. Sheng and J. Fu, 2006. Hospital indoor PM10/PM2.5 and associated trace elements in Guangzhou, China. Sci. Total Environ., 366: 124-135.
CrossRef  |  Direct Link  |  

25:  Song, W.W., M.R. Ashmore and A.C. Terry, 2009. The influence of passenger activities on exposure to particles inside buses. Atmos. Environ., 43: 6271-6278.
CrossRef  |  Direct Link  |  

26:  Massey, D., J. Masih, A. Kulshrestha, M. Habil and A. Taneja, 2009. Indoor/outdoor relationship of fine particles less than 2.5 μm (PM2.5) in residential homes locations in central Indian region. Build. Environ., 44: 2037-2045.
CrossRef  |  Direct Link  |  

27:  Zuraimi, M.S. and K.W. Tham, 2009. Reducing particle exposures in a tropical office building using electrostatic precipitators. Build. Environ., 44: 2475-2485.
CrossRef  |  Direct Link  |  

28:  Alshitawi, M.S. and H.B. Awbi, 2011. Measurement and prediction of the effect of students’ activities on airborne particulate concentration in a classroom. HVAC&R Res., 17: 446-464.
CrossRef  |  Direct Link  |  

29:  Morawska, L., G.A. Ayoko, G.N. Bae, G. Buonanno and C.Y.H. Chao et al., 2017. Airborne particles in indoor environment of homes, schools, offices and aged care facilities: The main routes of exposure. Environ. Int., 108: 75-83.
CrossRef  |  Direct Link  |  

30:  Amato, F., A. Alastuey, A. Karanasiou, F. Lucarelli and S. Nava et al., 2015. AIRUSE-LIFE+: A harmonized PM speciation and source apportionment in 5 Southern European cities. Atmos. Chem. Phys. Discuss., 15: 23898-24039.
CrossRef  |  Direct Link  |  

31:  Chithra, V.S. and S.M.S. Nagendra, 2018. A review of scientific evidence on indoor air of school building: Pollutants, sources, health effects and management. Asian J. Atmos. Environ., 12: 87-108.
CrossRef  |  Direct Link  |  

32:  Halios, C., M. Santamouris, A. Helmi, M. Kapsalaki, M. Saliari, A. Spanou and D. Tsakos, 2009. Exposure to fine particulate matter in ten night clubs in Athens Greece: Studying the effect of ventilation, cigarette smoking and resuspension. Sci. Total Environ., 407: 4894-4901.
CrossRef  |  Direct Link  |  

33:  Gao, J., C. Cao, X. Zhang and Z. Luo, 2013. Volume-based size distribution of accumulation and coarse particles (PM0.1–10) from cooking fume during oil heating. Build. Environ., 59: 575-580.
CrossRef  |  Direct Link  |  

34:  Challoner, A. and L. Gill, 2014. Indoor/outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2. Build. Environ., 80: 159-173.
CrossRef  |  Direct Link  |  

35:  Wong, N.H. and B. Huang, 2004. Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore. Build. Environ., 39: 1115-1123.
CrossRef  |  Direct Link  |  

36:  Seppanen, O., W.J. Fisk and Q.H. Lei, 2006. Ventilation and performance in office work. Indoor Air, 16: 28-36.
CrossRef  |  Direct Link  |  

37:  Jensen, K.L., H. Spiild and J.Toftum, 2012. Implementation of multivariate linear mixed-effects models in the analysis of indoor climate performance experiments. Int. J. Biometeorol., 56: 129-136.
CrossRef  |  Direct Link  |  

38:  Ponsoni, K. and M.S.G. Raddi, 2010. Indoor Air quality related to occupancy at an air-conditioned public building. Braz. arch. biol. technol., 53: 99-103.
CrossRef  |  Direct Link  |  

39:  Gupta, S., M. Khare and R. Goyal, 2007. Sick building syndrome-A case study in a multistory centrally air-conditioned building in the Delhi city. Build. Environ., 42: 2797-2809.
CrossRef  |  Direct Link  |  

40:  Mendell, M.J., W.J. Fisk, K. Kreiss, H. Levin and D. Alexander et al., 2002. Improving the health of workers in indoor environments: Priority research needs for a national occupational research agenda. Am. J. Public Health, 92: 1430-1440.
CrossRef  |  PubMed  |  Direct Link  |  

41:  Weschler, C.J., 2009. Changes in indoor pollutants since the 1950s. Atmos. Environ., 43: 153-169.
CrossRef  |  Direct Link  |  

42:  Mlhave, L., 2008. Inflammatory and allergic responses to airborne office dust in five human provocation experiments. Indoor Air, 18: 261-270.
CrossRef  |  Direct Link  |  

43:  Destaillats, H., R.L. Maddalena, B.C. Singer, A.T. Hodgson and T.E. McKone, 2008. Indoor pollutants emitted by office equipment: A review of reported data and information needs. Atmos. Environ., 42: 1371-1388.
CrossRef  |  Direct Link  |  

44:  He, C., L. Morawska and L. Taplin, 2007. Particle emission characteristics of office printers. Environ. Sci. Technol., 41: 6039-6045.
CrossRef  |  Direct Link  |  

45:  Qian, J., A.R. Ferro and K.R. Fowler, 2008. Estimating the resuspension rate and residence time of indoor particles. J. Air Waste Manage. Assoc., 58: 502-516.
CrossRef  |  Direct Link  |  

46:  Błaszczyk, E., W. Rogula-Kozłowska, K. Klejnowski, P. Kubiesa, I. Fulara and D. Mielżyńska-Švach 2017. Indoor air quality in urban and rural kindergartens: Short-term studies in Silesia, Poland. Air Qual. Atmos. Health, 10: 1207-1220.
CrossRef  |  Direct Link  |  

47:  Fromme, H., D. Twardella, S. Dietrich, D. Heitmann, R. Schierl, B. Liebl and H. Rüden, 2007. Particulate matter in the indoor air of classrooms-exploratory results from Munich and surrounding area. Atmos. Environ., 41: 854-866.
CrossRef  |  Direct Link  |  

48:  Guo, H., L. Morawska, C. He, Y.L. Zhang, G. Ayoko and M. Cao, 2010. Characterization of particle number concentrations and PM2. 5 in a school: Influence of outdoor air pollution on indoor air. Environ. Sci. Pollut. Res., 17: 1268-1278.
CrossRef  |  Direct Link  |  

©  2021 Science Alert. All Rights Reserved