ABSTRACT

Electrochemical methods as one of the Advanced Oxidation Processes (AOPs), have been applied effectively to degradation of recalcitrant organic in aqueous solutions. In the present study, the performance of Electro-Fenton (EF) method using iron electrodes on the oxidation of phenol was studied. This experimental study was performed in batch reactor and the effect of operating parameters such as solution pH, operating time, applied current, H2O2 and phenol concentration was investigated. In this study the H2O2 is manually added while a disposal iron anode is applied as a ferrous ion source. Experimental data indicated that pH, H2O2 and phenol concentration have principal role in the process. The results show that removal efficiency of phenol decreased with increasing pH, so that the maximum efficiency 26% was obtained at pH 10, also decreasing of H2O2 concentration decreased the efficiency. Optimal condition for removing 100% of phenol was found after 30 min of reaction at pH = 3.0, H2O2 concentration 100 mg L–1 and 5 mA cm–2. Electro-Fenton process using iron electrodes for phenol degradation and remediation of wastewater is a promising process in terms of environmental and low-cost features.

Services
Related Articles in ASCI
Search in Google Scholar
View Citation
Report Citation

 
  How to cite this article:

Ali Reza Rahmani, Amir Shabanloo, Jamal Mehralipour, Mehdi Fazlzadeh and Yousef Poureshgh, 2015. Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process. Research Journal of Environmental Sciences, 9: 332-341.

DOI: 10.3923/rjes.2015.332.341

URL: https://scialert.net/abstract/?doi=rjes.2015.332.341
 
Received: June 21, 2015; Accepted: August 10, 2015; Published: September 10, 2015



INTRODUCTION

Treatment of industrial wastewater is a problem of main concern at present. More stern regulations are being imposed, which persevere on the need to develop and apply treatment technologies effective to deal with the hazardous pollutants present-day in many industrial waste streams, wastewater compressing phenol and phenolic compounds presents a critical discharge problem due to their poor biodegradability, high toxicity and ecological features, phenols are large-scale distributed as environmental pollutants (Abdelwahab et al., 2009). Currently, phenol is produced at a rate of about 6 million t in year global, with a critical increasing trend (Busca et al., 2008). Phenol and phenolic compounds released into the surface water bodies in different from many industrial processes, including coking, synthetic rubber, pulp and paper, oil refineries, plastics, petrochemical, steel, conversion processes, phenolic resin industries and by different other chemical works (Abdelwahab et al., 2009; Babuponnusami and Muthukumar, 2011, 2012). Phenol has germane health effects for humans, this chemical compounds is quickly absorbed through the skin and can cause skin and eye burns upon touch, stupor, paroxysms, cyanosis and death can result from overexposure to it. Internally, phenol affects the liver, kidneys, lungs and vascular system. The ingestion of 1 g of phenol is fatal for man (Busca et al., 2008). Since, the Environmental Protection Agency (EPA) calls for reducing phenol amount in the wastewater to less than 1 mg L–1 (Abdelwahab et al., 2009). Generally studied methods for the treatment of wastewaters containing phenols and phenolic compounds include biological treatment (Fang et al., 2006), extraction (Kujawski et al., 2004), wet oxidation (Santos et al., 2006), electrocoagulation (Ugurlu et al., 2008) and chemical oxidation (Babuponnusami and Muthukumar, 2012). Phenol due to high solubility and stability makes its removal using traditional biologic treatment reasonably unachievable (Babuponnusami and Muthukumar, 2011). Though, Advanced Oxidation Processes (AOPs) have been widely used for the removal of large range of toxic organic pollutants from wastewater (Babuponnusami and Muthukumar, 2011, 2012). The important of AOPs, are Fenton, photo-Fenton, sono-Fenton (Babuponnusami and Muthukumar, 2012; Ranjit et al., 2008), electrochemical oxidation such as electro-Fenton (Jiang and Mao, 2012) methods. These process are based on the production of quickly and very reactive, non-selective, very powerful oxidizing agents such as hydroxyl radicals (OH) in solution, which have a powerful oxidative potential (E0 = 2.80 V vs. NHE) that is only lesser than fluorine (Brillas et al., 2005; Ghoneim et al., 2011). Due to the volatility of OH radical, it must be generated continuously "in situ" through chemical or photochemical reactions (Hao et al., 2000; Khataee et al., 2009). The Organic Matters (OMs) in the wastewater are attacked by hydroxyl radical, as explained in Eq. 1 (Khataee et al., 2009):

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(1)

Classic Fenton reaction (Fe2+/H2O2) is one of the most widely used AOPs for the degradation of a wide range of refractory organics such as dyes that cannot be oxidation biologically in effluents (Fan et al., 2010; Ma et al., 2005). In Fenton process the generation of hydroxyl radical is based on the electron transfer between hydrogen peroxide (H2O2) and a metal catalyst such as (Fe2+) (Ali et al., 1996). This process is explained in Eq. 2 (Babuponnusami and Muthukumar, 2012):

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(2)

But Fenton process has two main problems for large-scale used in the wastewater treatment: The first is that H2O2 expensive and the second is related to the operational pH, because Fe2+ and Fe3+ precipitated as a hydroxide at pH higher than 2-3 (Brillas et al., 2000; Brillas and Casado, 2002). A cooperation of electrochemical process and Fenton reaction, namely Electro-Fenton (EF) process, are combined to improve the oxidation of refractory organic compounds in wastewater (Umar et al., 2010). This method is divided into four groups: In type 1, H2O2 and Fe2+ are electro generation on a sacrificial anode and a cathode, respectively (Wang et al., 2010), in type 2, H2O2 is manually added while a sacrificial iron anode is applied as a Fe2+ source (Kurt et al., 2007; Sengil and Ozacar, 2006), in type 3, Fe2+ ion is manually added and H2O2 are electro generation using an oxygen sparging on cathode (Badellino et al., 2006) and in type 4, Fenton’s reagent is applied to generation OH in an electrolytic cell and ferrous ion is regenerated via the reduction of ferric ion at the cathode (Babuponnusami and Muthukumar, 2012).

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 1:Schematic of the electro-Fenton process and different groups of classification

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 2:Reaction mechanism of electro-Fenton process

Schematic of the EF process and different groups of classification showed in Fig. 1 (Rosales et al., 2012).

Electro-Fenton (EF) process is not using any harmful and toxic materials, it is an environment friendly and low-cost method for treatment of water and wastewater (Rosales et al., 2012). The main reaction of EF process explained in the Eq. 2-5 and Fig. 2 (Nidheesh and Gandhimathi, 2012):

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(3)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(4)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(5)

The objective of this study was to investigate the efficiency of EF process using iron electrodes in oxidation of phenol. In this regard, the effects of H2O2 and phenol concentration, pH, applied current and operating time were studied.

MATERIALS AND METHODS

Materials: Phenol (99.5% pure), hydrogen peroxide (30 wt. %), 4-aminoantipyrine, potassium ferricyanide, hydroxide ammonium, phosphate buffer, sodium hydroxide, sulfuric acid, sodium sulfate and all other reagents were obtained from Merck (Germany). The solutions were prepared by dissolving the adequate quantities of the compounds in distilled water. Stock solution (1000 mg L–1) of phenol was prepared by dissolving of 1 g phenol into distilled water. Experimental solutions of the desired concentrations of phenol were obtained by successive dilutions (50, 100, 150 and 200 mg L–1).

Experiments: Batch experiments were performed in the cylindrical glass cell (1250 mL) and filled with 1000 mL phenol solution of desired concentration for EF experiments. Electrochemical cell equipped with four electrodes that immersed into the solution, the iron cathode and anode of equal dimensions (2×20×200 mm) and the gap between the anode and cathode was 20 mm. A single-output adjustable DC power supply was used as the power supplier. Solution pH values were adjusted using reagent grade NaOH and/or sulfuric acid solutions with different molar concentrations. The pH of solutions was measured using a pH meter (Wagteck Mi. 151). Arrangements and experiments were realized at room temperature.

For improve conductivity and the ionic strength, added of 100 mg L–1 of Na2SO4 as the electrolyte. The mixture was stirred using a magnetic stirrer for 60 min, samples were taken from the electrochemical cell for each 15 min in all the experiments and centrifuged for 3 min at 4000 rpm before analysis. The effect of H2O2 concentration (25-100 mg L–1), initial pH (3-10), initial concentration of phenol (50-200 mg L–1), applied current (3.5-7 mA cm–2). The schema of the experimental apparatus showed in Fig. 3.

Analytical methods: The concentration of phenol was measured using direct photometric method, according to procedure of the standard methods for the examination of water and wastewater (5530 D) via UV-vis spectrophotometer (DR5000, HACH) by measuring the absorption at a wavelength of 500 nm. The obtained data were analyzed by the Excel software.

RESULTS AND DISCUSSION

Effect of pH: The effect of solution pH (3-10) on phenol degradation in EF process was studied and experimental data are shown in Fig. 4. This step of experiments was performed using initial phenol concentration of 50 mg L–1, H2O2 concentration of 100 mg L–1 and current density 5 mA cm–2. The results show that the solution pH in the phenol degradation was meaningful. The maximum phenol removal (>99.99%) was observed at pH 3. Increasing the pH from 3-10 decreased the efficiency from 100-26%. Also with increasing electrolysis time from 0-60 min, increase removal efficiency. Undoubted, the pH is one of the most important factors in the EF process, commonly Fenton and EF process was controlled in acidic solution, controls the electro generation of the hydroxyl radical and the concentration of ferrous ions conducted with solution pH (Nidheesh and Gandhimathi, 2012; Wang et al., 2008; Zhou et al., 2007).

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 3:Experimental setup of electro-Fenton process

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 4:
Effect of pH on phenol removal by electro-Fenton process (operation condition: Initial phenol 50 mg L–1, H2O2 100 mg L–1, Na2SO4 100 mg L–1 and current density 5 mA cm–2)

At higher pH, the efficiency of EF process decreases quickly, especially pH>5. This is due to the H2O2 is unstable and volatility in basic solution, H2O2 rapidly disintegrate to O2 and water (Nidheesh and Gandhimathi, 2012; Shemer and Linden, 2006). Also with an increase in pH decrease in oxidation potential of OH (Babuponnusami and Muthukumar, 2012) because iron species begin to precipitate as ferric hydroxides complexes (Nidheesh and Gandhimathi, 2012). These complexes would extra when the pH was greater than 9 (Babuponnusami and Muthukumar, 2012). Generally, all researches reported, optimum pH in EF process between 2-4 (Nidheesh and Gandhimathi, 2012; Umar et al., 2010).

Effect of current density: The influence of current density (3.5-7 mA cm–2) on the phenol degradation was studied, experiments was performed using initial phenol concentration of 50 mg L–1 of pH 3, H2O2 concentration of 100 mg L–1 and the results obtained are shown in Fig. 5. The results showed 100% phenol removal at 5 mA cm–2 after the 45 min of reaction while at 7 mA cm–2 100% degradation was observed in 30 min after of electrolyzing. The applied current in electrolyte, make the reduction of oxygen to the production of hydrogen peroxide at the cathode surface. Higher applied current, increases the quantity of hydrogen peroxide produced, thus increasing the concentration of hydroxyl radicals in the solution (Sankara Narayanan et al., 2003). Increase of applied current density in solution intimate, higher the applied voltage on the electrochemical cell (Wang et al., 2010). Also higher electro-regeneration of ferrous ion from ferric ion with increasing current (Eq. 6) (Nidheesh and Gandhimathi, 2012):

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(6)

But the efficiency of EF process will be less at highest current density efficiency, this is due to interfere reactions in the electrochemical system, the separation of oxygen at anode (Eq. 7) and the formation of hydrogen at cathode (Eq. 8) happen at a higher current. These reactions interfere with principal reactions such as reactions Eq. 9 and 6 (Nidheesh and Gandhimathi, 2012):

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(7)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(8)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(9)

Some studies reported that the current density in the EF process should be (6.4-10 A m–2) (Nidheesh and Gandhimathi, 2012).

Effect of H2O2 concentration: In this study the H2O2 is manually added and the effect of H2O2 concentration on phenol removal efficiency was studied at a constant phenol concentration of 50 mg L–1, pH 3 and applied current 5 mA cm–2. The results obtained are shown in Fig. 6. With increase H2O2 concentration increased the phenol degradation efficiency, the maximum phenol degradation of 100% were obtained with 100 mg L–1 of H2O2 in 30 min after the reaction.

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 5:
Effect of current density on phenol removal by electro-Fenton process (operation condition: Initial phenol 50 mg L–1, H2O2 100 mg L–1, Na2SO4 100 mg L–1, pH 3)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 6:
Effect of H2O2 concentration on phenol removal by electro-Fenton process (operation condition: Initial phenol 50 mg L–1, applied current 5 mA cm–2, Na2SO4 100 mg L–1, pH 3)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 7:
Effect of initial phenol concentration on phenol removal by electro-Fenton process (operation condition: H2O2 100 mg L–1, applied current 5 mA cm–2, Na2SO4 100 mg L–1, pH 3)

The initial concentration of H2O2 plays a critical role in the EF process, removal of pollutants increases with increase in H2O2 concentration. The increase in the removal efficiency was due to the increase in hydroxyl radical concentration as a result of the addition of H2O2 (Eq. 1) (Ting et al., 2009). But at a high concentration of H2O2, the decrease in removal efficiency was due to the hydroxyl radical scavenging effect of H2O2 (Eq. 10 and 11) (Nidheesh and Gandhimathi, 2012; Ting et al., 2009):

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(10)

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
(11)

Effect of initial phenol concentration: The effect of initial phenol concentration on the removal efficiency of phenol is shown in Fig. 7. These results show that whit increase the concentration of phenol from 50-200 mg L–1, the removal efficiency decreased from 100-46.85% after 30 min of electrochemical reaction. This is due to the fact that at a constant current density, the same number of iron ions and hydroxyl radical passes to the solution at different phenol concentrations (Babuponnusami and Muthukumar, 2012; Zazouli and Taghavi, 2012).

Image for - Degradation of Phenol in Aqueous Solutions Using Electro-Fenton Process
Fig. 8:Effect of EF process on solution pH (operation condition: Initial phenol 50 mg L–1, H2O2 100 mg L–1, applied current 5 mA cm–2)

Effect of Electro-Fenton (EF) process on final pH: In this step of experiments the effect of EF process on final pH was performed using initial phenol concentration of 50 mg L–1, H2O2 concentration of 100 mg L–1 and applied current 5 mA cm–2. The results show that the solution pH was increased during the EF process (Fig. 8). The increase in pH during electro-Fenton process leads to electrocoagulation whereby pollutants are removed by electrostatic attraction and/or complexation of reactions due to the conversion of Fe2+ and Fe3+ to Fe (OH)n (Mollah et al., 2001; Nidheesh and Gandhimathi, 2012).

CONCLUSION

Experimental data indicated that pH, H2O2 and phenol concentration have principal role in the process. The results show that removal efficiency of phenol decreased with increasing pH, so that the maximum efficiency 26% was obtained at pH 10, also decreasing of H2O2 concentration decreased the efficiency. Optimal condition for removing 100% of phenol was found after 30 min of reaction at pH = 3.0, H2O2 concentration 100 mg L–1 and 5 mA cm–2. Electro-Fenton process using iron electrodes for phenol degradation and remediation of wastewater is a promising process in terms of environmental and low-cost features.

REFERENCES

1:  Abdelwahab, O., N.K. Amin and E.S.Z. El-Ashtoukhy, 2009. Electrochemical removal of phenol from oil refinery wastewater. J. Hazard. Mat., 163: 711-716.
CrossRef  |  Direct Link  |  

2:  Babuponnusami, A. and K. Muthukumar, 2012. Advanced oxidation of phenol: A comparison between Fenton, electro-Fenton, sono-electro-Fenton and photo-electro-Fenton processes. Chem. Eng. J., 183: 1-9.
CrossRef  |  Direct Link  |  

3:  Babuponnusami, A. and K. Muthukumar, 2011. Degradation of phenol in aqueous solution by Fenton, sono-Fenton and sono-photo-Fenton methods. CLEAN-Soil Air Water, 39: 142-147.
CrossRef  |  Direct Link  |  

4:  Badellino, C., C.A. Rodrigues and R. Bertazzoli, 2006. Oxidation of pesticides by in situ electrogenerated hydrogen peroxide: Study for the degradation of 2,4-dichlorophenoxyacetic acid. J. Hazard. Mater., 137: 856-864.
CrossRef  |  Direct Link  |  

5:  Busca, G., S. Berardinelli, C. Resini and L. Arrighi, 2008. Technologies for the removal of phenol from fluid streams: A short review of recent developments. J. Hazard. Mater., 160: 265-288.
CrossRef  |  Direct Link  |  

6:  Brillas, E., J.C. Calpe and J. Casado, 2000. Mineralization of 2,4-D by advanced electrochemical oxidation processes. Water Res., 34: 2253-2262.
CrossRef  |  Direct Link  |  

7:  Brillas, E. and J. Casado, 2002. Aniline degradation by electro-Fenton® and peroxi-coagulation processes using a flow reactor for wastewater treatment. Chemosphere, 47: 241-248.
CrossRef  |  Direct Link  |  

8:  Brillas, E., I. Sires, C. Arias, P.L. Cabot, F. Centellas, R.M. Rodriguez and J.A. Garrido, 2005. Mineralization of paracetamol in aqueous medium by anodic oxidation with a boron-doped diamond electrode. Chemosphere, 58: 399-406.
CrossRef  |  Direct Link  |  

9:  Fan, Y., Z. Ai and L. Zhang, 2010. Design of an electro-Fenton system with a novel sandwich film cathode for wastewater treatment. J. Hazard. Mater., 176: 678-684.
CrossRef  |  Direct Link  |  

10:  Fang, H.H.P., D.W. Liang, T. Zhang and Y. Liu, 2006. Anaerobic treatment of phenol in wastewater under thermophilic condition. Water Res., 40: 427-434.
CrossRef  |  Direct Link  |  

11:  Ghoneim, M.M., H.S. El-Desoky and N.M. Zidan, 2011. Electro-Fenton oxidation of Sunset Yellow FCF azo-dye in aqueous solutions. Desalination, 274: 22-30.
CrossRef  |  Direct Link  |  

12:  Hao, O.J., H. Kim and P.C. Chiang, 2000. Decolorization of wastewater. Crit. Rev. Environ. Sci. Technol., 30: 449-505.
CrossRef  |  Direct Link  |  

13:  Jiang, L. and X. Mao, 2012. Degradation of phenol-containing wastewater using an improved electro-Fenton process. Int. J. Electrochem. Sci., 7: 4078-4088.
Direct Link  |  

14:  Khataee, A.R., V. Vatanpour and A.R.A. Ghadim, 2009. Decolorization of C.I. Acid Blue 9 solution by UV/nano-TiO2, Fenton, Fenton-like, electro-Fenton and electrocoagulation processes: A comparative study. J. Hazard. Mater., 161: 1225-1233.
CrossRef  |  Direct Link  |  

15:  Kujawski, W., A. Warszawski, W. Ratajczak, T. Porebski, W. Capala and I. Ostrowska, 2004. Removal of phenol from wastewater by different separation techniques. Desalination, 163: 287-296.
CrossRef  |  Direct Link  |  

16:  Kurt, U., O. Apaydin and M.T. Gonullu, 2007. Reduction of COD in wastewater from an organized tannery industrial region by electro-Fenton process. J. Hazard. Mater., 143: 33-40.
CrossRef  |  Direct Link  |  

17:  Ma, J., W. Song, C. Chen, W. Ma, J. Zhao and Y. Tang, 2005. Fenton degradation of organic compounds promoted by dyes under visible irradiation. Environ. Sci. Technol., 39: 5810-5815.
CrossRef  |  Direct Link  |  

18:  Mollah, M.Y.A., R. Schennach, J.R. Parga and D.L. Cocke, 2001. Electrocoagulation (EC)-science and applications. J. Hazard. Mater., 84: 29-41.
CrossRef  |  Direct Link  |  

19:  Nidheesh, P.V. and R. Gandhimathi, 2012. Trends in electro-Fenton process for water and wastewater treatment: An overview. Desalination, 299: 1-15.
CrossRef  |  Direct Link  |  

20:  Ranjit, P.J.D., K. Palanivelu and C.S. Lee, 2008. Degradation of 2,4-dichlorophenol in aqueous solution by sono-Fenton method. Korean J. Chem. Eng., 25: 112-117.
CrossRef  |  Direct Link  |  

21:  Rosales, E., M. Pazos and M.A. Sanroman, 2012. Advances in the electro-Fenton process for remediation of recalcitrant organic compounds. Chem. Eng. Technol., 35: 609-617.
CrossRef  |  Direct Link  |  

22:  Ali, S.A., J.R. Bolton and S.R. Cater, 1996. The use of iron in advanced oxidation processes. J. Adv. Oxidation Technol., 1: 18-26.
Direct Link  |  

23:  Sankara Narayanan, T.S.N., G. Magesh and N. Rajendran, 2003. Degradation of o-chlorophenol from aqueous solution by electro-Fenton process. Fresenius Environ. Bull., 12: 776-780.
Direct Link  |  

24:  Santos, A., P. Yustos, S. Gomis, G. Ruiz and F. Garcia-Ochoa, 2006. Reaction network and kinetic modeling of wet oxidation of phenol catalyzed by activated carbon. Chem. Eng. Sci., 61: 2457-2467.
CrossRef  |  Direct Link  |  

25:  Sengil, I.A. and M. Ozacar, 2006. Treatment of dairy wastewaters by electrocoagulation using mild steel electrodes. J. Hazard. Mater., 137: 1197-1205.
CrossRef  |  Direct Link  |  

26:  Shemer, H. and K.G. Linden, 2006. Degradation and by-product formation of diazinon in water during UV and UV/H2O2 treatment. J. Hazard. Mater., 136: 553-559.
CrossRef  |  Direct Link  |  

27:  Ting, W.P., M.C. Lu and Y.H. Huang, 2009. Kinetics of 2,6-dimethylaniline degradation by electro-Fenton process. J. Hazard. Mater., 161: 1484-1490.
CrossRef  |  Direct Link  |  

28:  Ugurlu, M., A. Gurses, C. Dogar and M. Yalcin, 2008. The removal of lignin and phenol from paper mill effluents by electrocoagulation. J. Environ. Manage., 87: 420-428.
CrossRef  |  PubMed  |  Direct Link  |  

29:  Umar, M., H.A. Aziz and M.S. Yusoff, 2010. Trends in the use of Fenton, electro-Fenton and photo-Fenton for the treatment of landfill leachate. Waste Manage., 30: 2113-2121.
CrossRef  |  Direct Link  |  

30:  Wang, C.T., W.L. Chou, M.H. Chung and Y.M. Kuo, 2010. COD removal from real dyeing wastewater by electro-Fenton technology using an activated carbon fiber cathode. Desalination, 253: 129-134.
CrossRef  |  Direct Link  |  

31:  Wang, C.T., J.L. Hu, W.L. Chou and Y.M. Kuo, 2008. Removal of color from real dyeing wastewater by electro-Fenton technology using a three-dimensional graphite cathode. J. Hazard. Mater., 152: 601-606.
CrossRef  |  Direct Link  |  

32:  Zazouli, M.A. and M. Taghavi, 2012. Phenol removal from aqueous solutions by electrocoagulation technology using iron electrodes: Effect of some variables. J. Water Resour. Protect., 4: 980-983.
CrossRef  |  Direct Link  |  

33:  Zhou, M., Q. Yu, L. Lei and G. Barton, 2007. Electro-Fenton method for the removal of methyl red in an efficient electrochemical system. Sep. Purif. Technol., 57: 380-387.
CrossRef  |  Direct Link  |  