Asian Science Citation Index is committed to provide an authoritative, trusted and significant information by the coverage of the most important and influential journals to meet the needs of the global scientific community.  
ASCI Database
308-Lasani Town,
Sargodha Road,
Faisalabad, Pakistan
Fax: +92-41-8815544
Contact Via Web
Suggest a Journal
 
Articles by Z. Kadir Saritas
Total Records ( 2 ) for Z. Kadir Saritas
  Kamuran Pamuk , Z. Kadir Saritas , Ibrahim Demirkan and Musa Korkmaz
  The aim of the study was to compare the clinical usage of filling materials such as amalgam, glass ionomer cement and resin composite. A 2 years old male and weighing 16 kg stray dog, was used. Cavities were made in a routine manner by a frez. Cavities of the buccal surfaces of the left maxillar molar, premolar, canine and incisive teeth were filled with amalgam, cavities of the buccal surfaces of the left mandibular molar, premolar, canine and incisive teeth were filled with glass ionomer cement and cavities of the buccal surfaces of the right mandibular molar, premolar, canine and incisive teeth were loaded with resin composite. The dog was monitored for a period of 6 months for the applicability of dental restorative materials. It was concluded that amalgam and resin composite were more usable than glass ionomer cement in teeth, which were exposed to stress however, resin composite as a restorative material is more demandable if esthetical reason is preferred in veterinary dentistry.
  Kamuran Pamuk , Z. Kadir Saritas , Ibrahim Demirkan , Abuzer Acar , Musa Korkmaz and Duygu Baki Acar
  One of the main cause of stress in livestock is the vision problems. The goal of this study was to determine Intraocular Pressure (IOP) in Anatolian Buffaloes (AB) by means of applanation tonometry using Tono-Pen XL for the investigation of a stress factor in welfare of the anatolian buffaloes. A total of 2118 eyes were examined from 1059 apparently healthy AB aged between 1 and 8 years old from both sexes. IOP of AB were measured with Tono-Pen XL three times for each eyes in the morning at noon and in the evening during afternoon examination. IOPs of the left eyes were found to be 22.05±2.68 mmHg (range 16.5-27.3 mmHg) whereas the right eyes were 22.07±2.68 mmHg (range 16.1-27.0 mmHg). Comparison of the tonometry between the right and left eyes of AB showed no significant difference. IOP was decreased in accordance with the age of the animal. To the knowledge, this is the 1st report of tonometrical investigation performed in AB. It was determined that IOP for AB could be 22.05±2.68 mmHg (range 16.1-27.3 mmHg).
 
 
 
Copyright   |   Desclaimer   |    Privacy Policy   |   Browsers   |   Accessibility