Asian Science Citation Index is committed to provide an authoritative, trusted and significant information by the coverage of the most important and influential journals to meet the needs of the global scientific community.  
ASCI Database
308-Lasani Town,
Sargodha Road,
Faisalabad, Pakistan
Fax: +92-41-8815544
Contact Via Web
Suggest a Journal
 
Articles by T Lee
Total Records ( 2 ) for T Lee
  A. J Hayanga , D Mukherjee , D Chang , H Kaiser , T Lee , S Gearhart , N Ahuja and J. Freischlag
 

Objective  To compare risk- and volume-adjusted outcomes of colon resections performed at teaching hospitals (THs) vs non-THs to assess whether benign disease may influence the volume-outcome effect.

Design  Retrospective data analysis examining colon resections determined by International Classification of Diseases, Ninth Revision, Clinical Modification classification performed in the United States from 2001 through 2005 using the Nationwide Inpatient Sample (NIS) and the Area Resource File (2004). Patient covariates used in adjustment included age, sex, race, Charlson Index comorbidity score, and insurance status. Hospital covariates included TH status, presence of a colorectal surgery fellowship approved by the Accreditation Council for Graduate Medical Education, geographical region, institutional volume, and urban vs rural location. County-specific surgeon characteristics used in adjustment included average age of surgeons and proportion of colorectal board-certified surgeons within each county. Environmental or county covariates included median income and percentage of county residents living below the federal poverty level.

Setting  A total of 1045 hospitals located in 38 states in the United States that were included in the NIS.

Patients  All patients older than 18 years who had colon resection and were discharged from a hospital included in the NIS.

Main Outcome Measures  Operative mortality, length of stay (LOS), and total charges.

Results  A total of 115 250 patients were identified, of whom 4371 died (3.8%). The mean LOS was 10 days. Fewer patients underwent surgical resection in THs than in non-THs (46 656 vs 68 589). Teaching hospitals were associated with increased odds of death (odds ratio, 1.14) (P = .03), increased LOS (P = .003), and a nonsignificant trend toward an increase in total charges (P = .36).

Conclusions  With the inclusion of benign disease, colon surgery displays a volume-outcome relationship in favor of non-THs. Inclusion of benign disease may represent a tipping point.

  T Lee , S. W Kim , W. P Chisholm , J Slaven and M. Harper
 

The American Conference of Governmental Industrial hygienists (ACGIH) lowered the threshold limit value (TLV) for respirable crystalline silica (RCS) exposure from 0.05 to 0.025 mg m–3 in 2006. For a working environment with an airborne dust concentration near this lowered TLV, the sample collected with current standard respirable aerosol samplers might not provide enough RCS for quantitative analysis. Adopting high flow rate sampling devices for respirable dust containing silica may provide a sufficient amount of RCS to be above the limit of quantification even for samples collected for less than full shift. The performances of three high flow rate respirable samplers (CIP10-R, GK2.69, and FSP10) have been evaluated in this study. Eleven different sizes of monodisperse aerosols of ammonium fluorescein were generated with a vibrating orifice aerosol generator in a calm air chamber in order to determine the sampling efficiency of each sampler. Aluminum oxide particles generated by a fluidized bed aerosol generator were used to test (i) the uniformity of a modified calm air chamber, (ii) the effect of loading on the sampling efficiency, and (iii) the performance of dust collection compared to lower flow rate cyclones in common use in the USA (10-mm nylon and Higgins–Dewell cyclones). The coefficient of variation for eight simultaneous samples in the modified calm air chamber ranged from 1.9 to 6.1% for triplicate measures of three different aerosols. The 50% cutoff size (50dae) of the high flow rate samplers operated at the flow rates recommended by manufacturers were determined as 4.7, 4.1, and 4.8 µm for CIP10-R, GK2.69, and FSP10, respectively. The mass concentration ratio of the high flow rate samplers to the low flow rate cyclones decreased with decreasing mass median aerodynamic diameter (MMAD) and high flow rate samplers collected more dust than low flow rate samplers by a range of 2–11 times based on gravimetric analysis. Dust loading inside the high flow rate samplers does not appear to affect the particle separation in either FSP10 or GK2.69. The high flow rate samplers overestimated compared to the International Standards Organization/Comité Européen de Normalisation/ACGIH respirable convention [up to 40% at large MMAD (27.5 µm)] and could provide overestimated exposure data with the current flow rates. However, both cyclones appeared to be able to provide relatively unbiased assessments of RCS when their flow rates were adjusted.

 
 
 
Copyright   |   Desclaimer   |    Privacy Policy   |   Browsers   |   Accessibility