  P. Meena , S. Rittidech and P. Tammasaeng
  This research aims to the effect of evaporator section lengths and working fluids on operational limit of closed loop oscillating heat pipes with check valves (CLOHP/CV) with R123 Ethanol and Water were used as the working fluids. A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 mm inside diameter: 10 turns: 5, 10 and 15 cm equal lengths for evaporator, adiabatic and condenser sections. The working fluid was filled in the tube at the filling ratio of 50%. The evaporator section was given heat by heater while the condenser section was cooled by volume water in a cold bath. The adiabatic section was properly insulated. In the test operation. Which the temperature at the adiabatic section was controlled at 60°C in steady-state condition. From The obtained results obtained, it could be concluded as follows. When the evaporator lengths increased from 5 cm to 10 and 15 cm the critical heat transfer flux decreased. There was working fluids change from R123 to Ethanol and water the critical heat flux decreased.
  P. Meena and S. Rittidech
  This research was to study the comparisons of heat transfer performance of closed-looped oscillating heat pipe and closed-looped oscillating heat pipe with check valves heat exchangers with R134a, Ethanol and water were used as the working fluids. A set of heat pipe heat exchanger (CLOHP and CLOHP/CV) were made of copper tubes in combination of following dimension: 2.03 mm inside diameter: 40 turns, with 20, 10 and 20 cm for evaporator, adiabatic and condenser sections lengths. The working fluid was filled in the tube at the filling ratio of 50%. The evaporator section was given heat by heater while the condenser section was cooled by air. The adiabatic section was properly insulated. In the test operation, it could be concluded as follows. It indicated that the heat transfer performance of closed-looped oscillating heat pipe with check valves heat exchanger better than closed-looped oscillating heat exchanger.
  P. Meena , S. Rittidech and P. Tammasaeng
  This research was to study the effect of inner diameter and inclination angles on operation limit of a Closed Loop Oscillating Heat Pipes with Check Valves (CLOHP/CV). A set of CLOHP/CV was made of copper tubes in combination of following dimension: 1.77 and 2.03 mm inside diameter: 10 turn, with R123 was used as the working fluid. The working fluid was filled in the tube at the filling ratio of 50%. The inclination angles were 0, 20, 40, 60, 80 and 90° with 5 equal lengths for evaporator, adiabatic and condenser sections. The evaporator section was given heat by heater while the condenser section was cooled by volume water in a cold bath. The adiabatic section was properly insulated. In the test operation, it could be concluded as follows. It indicated that when the inner diameter changed from 1.77-2.03 mm the critical temperature increased. And when increase the inclination angles from 0 until to 90° the critical temperature increased.
  P. Meena and S. Rittidech
  This study aims to design, construct and test the waste heat recovery by closed-loop oscillating heat pipe with check valve from pottery kilns for energy thrift, were used the working fluids with a filling ratio of 50%. The (CLOHO/CV) was made of copper capillary tube with inside diameter of 2.03 mm. The lengths of evaporator and condenser section were 20 cm. The lengths of adiabatic section 10 cm. The number of turn was 40 meandering turns. The ratio of number of check valves was 0.04. The evaporator section was heated by hot gas, while the condenser section was cooled by fresh air. From the experiment, it indicated that the working fluid changes form water to R123, the heat transfer rate increased to 4,800 and 7,900 Watts and the effectiveness increased from 0.32 to 0.44. The CLOHP/CV heat exchanger can reduce the quantity of using gas in pottery kilns and achieve energy thrift.
 
 
 