Asian Science Citation Index is committed to provide an authoritative, trusted and significant information by the coverage of the most important and influential journals to meet the needs of the global scientific community.  
ASCI Database
308-Lasani Town,
Sargodha Road,
Faisalabad, Pakistan
Fax: +92-41-8815544
Contact Via Web
Suggest a Journal
 
Articles by J.A. Laoye
Total Records ( 3 ) for J.A. Laoye
  R.K. Odunaike , V.U. Chukwuma , E.B. Ejiwunmi , J.A. Laoye , A.O. Williams and T.O. Ogunwale
  This study presents the study of effect of weak magnet fields on the haemotological and some Histological parameters of Albino rats exposed for a period of 6 h per day for 2 weeks. Analysis on these parameters clearly showed that no significant differences were observed in both the haemotological and histological studies and therefore poses no serious health risk of any kind. It however recommends that GSM users should not be scared of the usage of their cell phones but to avoid abuse at instantaneous period because the somatic changes might result in late biological injury.
  R.K. Odunaike , A.A. Oberafo , M.G. Zebaze Kana and J.A. Laoye
  The geometrical effect of probe shape in a two point arrangements were investigated by measuring the surface electrical current density-voltage (J-V) characteristics as deposited thin films of tellurium with antimony probes. The chosen geometry of antimony probes in contact with the Te-samples were triangles, rectangles, semicircles and segments of circles whose each pair was of 2 types of probe extension. The first was the uniform electrode width configuration in which the metal (Sb) electrode width was continuous at the edge of the Te-sample while the second was the differential electrode configuration is which the metal electrode width was discontinuous as the edge of the Te-sample region. The results showed that the surface density-voltage characteristics were linear in every case. The rectangular electrode pair gave the least values, followed by the semi-circular pair and finally the triangular pair. In the latter 2 cases, the results for both uniform and differential electrode width configuration were practically the same.
  I.A. Asaolu , R. Kola Odunaike and J.A. Laoye
  The possibility of magnetic order in a sample depends on its spatial dimensionality and order parameter components. Mermin and Wagner proved that no magnetic order, ferromagnetic or antiferromagnetic, exists in an isotropic Heisenberg, Ising or XY 2 dimensional (2d) magnet. However, Onsager and some other scientists proved that under certain conditions of temperature in Ising model and anisotropy, transition to order is possible in 2d’ magnetic material. SQUID is the most modern and sensitive of all non-destructive evaluation instruments of all magnetic detectors. A 2d Mangense Stearate (MnSt2) sample was fabricated, mounted and moved along the axis of a SQUID magnetometer. Magnetic flux simulation for the design of an ideal axial sample and holder configuration expected of such sample is hereby considered.
 
 
 
Copyright   |   Desclaimer   |    Privacy Policy   |   Browsers   |   Accessibility