Articles by H.H. Masjuki
Total Records ( 10 ) for H.H. Masjuki
  Liaquat Ali Memon , T.M.I. Mahlia and H.H. Masjuki
  This research investigates the possibilities of potential savings and reduction in Green House Gas (GHG) emissions caused by road transport in general and private cars in particular. Private cars use a large share of the transport fuel, thus these are the major and ever increasing contributor to the GHG emissions. An extensive review of international experiences on fuel economy standards and labels, in order to encounter the problem, is carried. The possibilities of the implementation of fuel economy standards and labels for motor vehicles in Pakistan are examined. Based on the studies carried out in developed countries, results have shown that the implementation of fuel economy standards and labels for motor vehicles in developing countries like Pakistan would be beneficial for the society, government as well as environment.
  M. Hasanuzzaman , R. Saidur and H.H. Masjuki
  This study presents the effects of different operating variables on energy consumption of refrigerator-freezer that had two phases. The first phase is to investigate the effects of the number of door opening, duration of each door remain open, ambient temperature, cabinet load and thermostat setting position on energy consumption during the open door conditions. The second phase is to investigate the effects of the ambient temperature, cabinet load, thermostat setting position and open surface water pan area inside the cabinet on energy consumption during the closed door conditions. All the experiments were conducted in the environmental controlled chamber. The result shows that there is a great influence of different variables on energy consumption and average consumption is about 3.3 kWh day-1. The effects of number of door opening, ambient temperature and cabinet load are more compared to the others. The open door energy consumption is 40% more compared to the closed door test. It is found that the average of the maximum energy consumption is 27.3% more compared to average consumption and 55.6% more compared to average of the minimum consumption. If the users be serious, a significant amount of energy could be saved with the proper utilization of refrigerator-freezer.
  R. Saidur , M.M. Hasan , A.S.M.A. Haseeb and H.H. Masjuki
  In this study, the recent trends for optical coatings in glass industries have been explored for the variety of climate dependent applications. Different coated glazings have been presented with their optical and thermal characteristics. A comparative analysis among types of coated products is also performed. It has been observed that for warm climate it is necessary to block near infra red portion of sunlight to reduce solar heat gain through windows. On the other hand, for cold climate it is necessary to allow the whole portion of light and it is necessary to block the IR radiation from escaping out to keep the interior space warm. For this purpose, Ag or Ag-alloy metallic thin film meet the requirements but they reduce visible transmittance as well. So for increasing visible transmittance, a dielectric layer of high refractive index is required. Here a variety of dielectric layers are studied. Finally for reaching the goal of low energy buildings in both warm and cold climates, appropriate optical coatings for architectural flat glass have been recommended.
  R. Saidur and H.H. Masjuki
  In this study, the energy consumption of 149 domestic refrigerators has been monitored in Malaysian households. A questionnaire was used to get relevant information regarding the usage of this appliance in the actual kitchen environment to feed into neural networks. Prediction performance of Artificial Neural Networks (ANN) approach was investigated using actual monitored and survey data. Statistical analyses in terms of fraction of variance R2, Coefficient of Variation (COV), RMS are calculated to judge the performance of NN model. It has been found that the regression coefficient R2 is very close to unity for the best prediction performance results.
  R. Saidur , H.H. Masjuki , M. Hasanuzzaman and G.S. Kai
  This study carried out the field survey from house to house to garner the information of consumer behavior. In this study the energy consumption 104 refrigerators have been monitored as well. The energy consumption of 104 refrigerators is clustered and segmented to classify the refrigerators of same characteristic in the same group. The capacity of the refrigerator, frequency of door opening and position of refrigerator either near heat source or away from the heat source is considered for clustering and segmentation analysis. The clustering and segmentation in this survey reveal the effect of these factors on the energy performance of the refrigerator.
  R. Saidur , M.I. Jahirul , M. Hasanuzzaman and H.H. Masjuki
  Experiments were conducted to investigate the engine`s emission at the different operating conditions. The tests were conducted by varying the engine speed, throttle opening and operating time. During the experimental investigation, the operating variables were varied (engine speed from 1500 to 2500 rpm; throttle percentage from 25 to 36% and operating time from 2.5 to 5 min) according to the experimental schedule set up. These emission models reveal the effects of each parameter`s significance and adequacy for the design range which evaluated using ANOVA F-test. The effects of each parameter in emission response are studied through the response model. From the comparative evaluation of the experimental results for the different operating conditions, it is revealed that there is an influence of the engine speed, throttle position and operating time. From the analysis, it is concluded that emissions are more affected on engine speed and throttle position.
  R. Saidur , M. Hasanuzzaman , M.M. Hasan and H.H. Masjuki
  This study presents the Overall Thermal Transfer Value (OTTV) and the energy consumption of room air conditioners of the residential buildings in Malaysia. A survey has been conducted to investigate the OTTV and the energy consumption of room air conditioners of the residential buildings in Malaysia. OTTV calculation, energy consumption and effect of the building parameters on energy consumption have been investigated. It is found that OTTV of the residential buildings in Malaysia varied from 35 to 65 W m-2 with a mean value of 41.7 W m-2. The sensitivities of several parameters such as window to wall ratio (WWR), Shading Coefficient (SC), U-value for wall (Uw) and solar absorption (α) are provided to design and optimize the thermal performance of residential buildings. It is found that U and α influence more on OTTV compared to other parameters. The analysis shows that about 14, 10 and 5% of residential building air conditioners have annual electricity consumption in the ranges 500 to 1000 kWh, 1000 to 2000 kWh and 7500 to 10000 kWh, respectively. The maximum, minimum and average annual electricity consumption of the air conditioner of residential buildings is 22055.5, 136.1 and 3708.8 kWh, respectively.
  M.M. Hasan , A.S.M.A. Haseeb , R. Saidur , H.H. Masjuki and M. Hamdi
  In this investigation, anatase TiO2 thin films were deposited on glass substrates at room temperature by RF magnetron sputtering at an elevated sputtering pressure of 3 Pa. The TiO2 films deposited at room temperature were annealed at different temperatures up to 873°K for 1 h. The TiO2 films were characterized by X-Ray Diffraction (XRD), Field-Emission Scanning Electron Microscopy (FESEM), Atomic Force Microscopy (AFM) and UV-visible-NIR spectrophotometry. The XRD results reveal that the as-deposited film possess the anatase structure. Annealed TiO2 films show an insignificant change in crystallinity except of the fact that there is a slight increase for the film annealed at 600°C. The crystallite size increases from 44.5 to 48 nm with the increase of the annealing temperature. As-grown TiO2 film exhibits high visible transmittance with enhanced refractive index of 2.31 at a wavelength of 550 nm. The indirect optical band gaps of the as-deposited and annealed films have been estimated to be in the range of 3.39-3.42 eV. AFM observations reveal the compact and dense morphology of the as-deposited and annealed TiO2 thin films.
  S.C. Pang , H.H. Masjuki , M.A. Kalam and M.A. Hazrat
  Current research performs mathematics correlations between engine speed, coolant flow, vehicle speed and driving gear. A step-by-step procedure is described to obtain the engine cooling system parameters mathematically (include a CFD model). After obtaining the parameters, the thermal equilibrium of engine cooling system is studied thoroughly. The study of thermal equilibrium provides some insights on how to reduce engine cooling load and when the interference of cooling fan is required. A segmented spread sheet model is developed in order to explain the phenomenon which air flow driven by uniform ram air could dissipate higher amount of heat flow than air flow driven by cooling fan. The segmentation analysis concluded that minimum mCp fluid is switched to coolant when the air flow is concentrated at small portion of area.
  M. Tajally , Z. Huda and H.H. Masjuki
  The present study reports the effect of cold working on bending and tensile behavior of 7075 Al alloy. A series of experiments involving cold rolling (58% cold work) have been conducted for the 7075-O aluminum alloy. It has been shown that cold rolling has a significant effect on increasing the yield strength and decreasing ductility of alloy. The variation in alloy ductility was found to correlate well with the fractography results of the tensile and bending tested specimens. The SEM fractographs of fractured surfaces for cold rolled specimens can be show very clearly the ductile to brittle transition behavior (absence of dimples) in bending test. It has been shown that, 7075-O aluminum alloy before cold rolling exhibits excellent bend properties so that, it is capable of being bent cold around a pin under high angle without crack or fracture, due to ductile behavior. Also, it can be seen that surface quality of starting materials is better than of cold rolled samples.
 
 
 