Comparison of powered and conventional air-purifying respirators during simulated resuscitation of casualties contaminated with hazardous substances

J Schumacher    

Abstract: Background:

Advanced life support of patients contaminated with chemical, biological, radiological or nuclear (CBRN) substances requires adequate respiratory protection for medical first responders. Conventional and powered air-purifying respirators may exert a different impact during resuscitation and therefore require evaluation. This will help to improve major incident planning and measures for protecting medical staff.

Methods:

A randomised crossover study was undertaken to investigate the influence of conventional negative pressure and powered air-purifying respirators on the simulated resuscitation of casualties contaminated with hazardous substances. Fourteen UK paramedics carried out a standardised resuscitation algorithm inside an ambulance vehicle, either unprotected or wearing a conventional or a powered respirator. Treatment times, wearer mobility, ease of communication and ease of breathing were determined and compared.

Results:

In the questionnaire, volunteers stated that communication and mobility were similar in both respirator groups while breathing resistance was significantly lower in the powered respirator group. There was no difference in mean (SD) treatment times between the groups wearing respiratory protection and the controls (245 (19) s for controls, 247 (17) s for conventional respirators and 250 (12) s for powered respirators).

Conclusions:

Powered air-purifying respirators improve the ease of breathing and do not appear to reduce mobility or delay treatment during a simulated resuscitation scenario inside an ambulance vehicle with a single CBRN casualty.