Subscribe Now Subscribe Today
Science Alert
 
Blue
   
Curve Top
Journal of Applied Sciences
  Year: 2012 | Volume: 12 | Issue: 5 | Page No.: 473-479
DOI: 10.3923/jas.2012.473.479
 
Facebook Twitter Digg Reddit Linkedin StumbleUpon E-mail

Thermal Comfort Assessment of Underfloor vs. Overhead Air Distribution System

M. Aghakhani and Gh. Eslami

Abstract:
This study presents numerical simulations of thermal comfort and contaminant removal in an air conditioned office room with two typical air distribution systems: under-floor and overhead. Well-known finite volume method was employed in 3D and 2nd order upwind scheme was used to discretize governing equations. SIMPLE algorithm was used for coupling velocity and pressure fields. Then, set of algebraic equations were solved in an iterative manner using ADI approach. After evaluating the utilized numerical approach by comparison of its results with the experimental data taken from relative literature, the study was expanded to reveal the effect of inlet position (Under-Floor Air Distribution (UFAD) system, angle of air inlet (Over Head Air Distribution (OHAD) system and comparison between two systems. Velocity, temperature, relative humidity, contaminant concentration, thermal sensation, Predicted Mean Vote (PMV) and contaminant removal factor was computed and used for assessing thermal comfort and contaminant removal characteristics of the office room in each under-investigation case. Results suggest that better thermal sensation and contaminant removal effectiveness may be obtained if typical air inlet diffuser setup used in both air distribution systems. Both simulated air distribution system, showed comparable thermal sensation. PMV was close to comfort zone in both configurations. The UFAD system had some advantages to OHAD system, especially in contaminant removal effectiveness.
PDF Fulltext XML References Citation Report Citation
 RELATED ARTICLES:
  •    Transient Cooling Load Characteristic of an Academic Building, using TRNSYS
  •    Assessment of Environmental Factors and Thermal Comfort at Automotive Paint Shop
  •    Thermal Comfort Evaluation of the Enclosed Transitional Space in Tropical Buildings: Subjective Response and Computational Fluid Dynamics Simulation
  •    Numerical Study of the Natural Ventilation in House: Cases of Three Rectangular Scale Models
How to cite this article:

M. Aghakhani and Gh. Eslami, 2012. Thermal Comfort Assessment of Underfloor vs. Overhead Air Distribution System. Journal of Applied Sciences, 12: 473-479.

DOI: 10.3923/jas.2012.473.479

URL: https://scialert.net/abstract/?doi=jas.2012.473.479

COMMENT ON THIS PAPER
 
 
 

 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

Curve Bottom