HOME JOURNALS CONTACT

Journal of Applied Sciences

Year: 2006 | Volume: 6 | Issue: 9 | Page No.: 2010-2013
DOI: 10.3923/jas.2006.2010.2013
Information Fusion Technology with Application to the Localization of Pipeline Leakage Based on Negative Pressure Wave Detection
Er Li, Yuehua Fan and Xinde Li

Abstract: In this study, aiming to the problem of poor precision of localization or mistaken detection suffering from the influence of the noise and the burying status of observable spot through the negative pressure wave detection, especially, under the condition of leakage multi-source, we often find the phenomena of mistaken detection. To improve the precision and correctness of localization, we propose a kind of information fusion technology used to detect the leakage of water pipeline. Here firstly we adopted the clustering method of ISODATA (Iterative Self-Organization Data Analysis Techniques Algorithm) to classify the leakage multi-source and then give a more precise localization with the weighted average method to integrate the information from every leakage source. At last, an example is illustrated to testify the validity of this method.

Fulltext PDF Fulltext HTML

How to cite this article
Er Li, Yuehua Fan and Xinde Li, 2006. Information Fusion Technology with Application to the Localization of Pipeline Leakage Based on Negative Pressure Wave Detection. Journal of Applied Sciences, 6: 2010-2013.

Related Articles:
© Science Alert. All Rights Reserved