Abstract: This study describes thermal modeling and its validation of greenhouse fishpond system connected with and without Flat Plate Collector (FPC). Numerical computation has been performed for a typical winter day in the month of December, 2005. The energy balance equations have been written considering the effects of conduction, convection,radiation, evaporation and ventilation and these equations are numerically solved with MATLAB 7.0 software to predict the room and water temperature. A parametric study has also been performed to find the effects of water mass and number of collectors. There is significant effect on water temperature at different water depths due to change in the number of collectors. The results showed that a rise of 4.13-6.92°C water temperature can be achieved for greenhouse pond connected with two number collectors and in case of without collector it was 3.12-5.64°C. Fish production in greenhouse is also significantly higher as compared to open pond. In both the cases, with and without collector predicted and experimental values of water temperature exhibited fair agreement with coefficient of correlation r = 0.96 and 0.95 and root mean square percent deviation e = 1.64 and 1.83%, respectively.