• [email protected]
  • +971 507 888 742
Submit Manuscript
SciAlert
  • Home
  • Journals
  • Information
    • For Authors
    • For Referees
    • For Librarian
    • For Societies
  • Contact
  1. Journal of Medical Sciences
  2. Vol 9 (4), 2009
  3. 185-193
  • Online First
  • Current Issue
  • Previous Issues
  • More Information
    Aims and Scope Editorial Board Guide to Authors Article Processing Charges
    Submit a Manuscript

Journal of Medical Sciences

Year: 2009 | Volume: 9 | Issue: 4 | Page No.: 185-193
DOI: 10.3923/jms.2009.185.193

Facebook Twitter Digg Reddit Linkedin StumbleUpon E-mail

Article Trend



Total views 3124

Search


Authors


W.K.B.A. Owiredu


G. Amegatcher


N. Amidu


Keywords


  • Diabetes
  • glucose meters
  • glucose oxidase method
  • accuracy
  • precision
Research Article

Precision and Accuracy of Three Blood Glucose Meters: Accu-Chek Advantage, One Touch Horizon and Sensocard

W.K.B.A. Owiredu, G. Amegatcher and N. Amidu
This study evaluated the accuracy and precision associated with the use of three popular alternative-site blood glucose monitors, Accu-chek Advantage, Onetouch Horizon and Sensocard, using forearm venous blood samples and capillary blood samples. The study was conducted from January to March, 2009 at the Komfo Anokye Teaching Hospital, Kumasi. One hundred and ninety consenting subjects were included in the study. The blood glucose levels were analyzed on glucose meters; Accu-chek Advantage, Sensocard and Onetouch Horizon by finger stick, using amperometry Technology. At the same time venous blood glucose was analyzed using the WHO reference Glucose Oxidase Method (GOD). The mean value generated by the WHO reference method (7.91±0.35) was not significantly different (p = 0.2816) from that produced by the Accu-chek Advantage (8.46±0.36), Sensocard (7.72±0.35; p = 0.7028) and Onetouch Horizon (7.97±0.35; p = 0.9044). Bland-Altman analysis indicates that Onetouch Horizon and Accu-chek Advantage have the tendency of overestimating blood glucose with a bias of -0.1 and -0.5, respectively. Sensocard could under-estimate with a bias of 0.2. In terms of rating, while all the glucose meters gave precisions at about the same level (i.e., 1.0), Onetouch Horizon is generating the closest value to the reference method with a difference between mean of -0.06, followed by Sensocard of 0.19 and Accu-chek Advantage with a value of -0.55. The precision of the Accu-chek Advantage, Onetouch Horizon and Sensocard for blood glucose monitoring from about 3.1-33.3 mmol L-1 is good. However, the Accu-chek Advantage has the tendency to overestimate at the hypoglycaemic levels. The Accu-chek Advantage is capable of estimating both capillary and venous blood glucose to the same level of accuracy. The Onetouch Horizon and Sensocard are however incapable of efficiently estimating venous blood glucose.
PDF Fulltext XML References Citation

How to cite this article

W.K.B.A. Owiredu, G. Amegatcher and N. Amidu, 2009. Precision and Accuracy of Three Blood Glucose Meters: Accu-Chek Advantage, One Touch Horizon and Sensocard. Journal of Medical Sciences, 9: 185-193.

DOI: 10.3923/jms.2009.185.193

URL: https://scialert.net/abstract/?doi=jms.2009.185.193

Comments


Francis Kyei Bugyei Reply
04 August, 2009

This is a very great paper. Flawless statistics, and the methodology was excellent. I think it's a great paper beneficial for lab practitioners and medical doctors.

Dr Soiker Davis Reply
14 August, 2023

As a dentist and knowing that there is a huge link between gum disease and diabetes, I love to have an in office device/method for testing blood sugar. Is there a saliva test? Can I use crevicular blood samples from bleeding gums. Please advise
Sincerely
Dr Spiker Davis

Leave a Comment


Your email address will not be published. Required fields are marked *

Useful Links

  • Journals
  • For Authors
  • For Referees
  • For Librarian
  • For Socities

Contact Us

Office Number 1128,
Tamani Arts Building,
Business Bay,
Deira, Dubai, UAE

Phone: +971 507 888 742
Email: [email protected]

About Science Alert

Science Alert is a technology platform and service provider for scholarly publishers, helping them to publish and distribute their content online. We provide a range of services, including hosting, design, and digital marketing, as well as analytics and other tools to help publishers understand their audience and optimize their content. Science Alert works with a wide variety of publishers, including academic societies, universities, and commercial publishers.

Follow Us
© Copyright Science Alert. All Rights Reserved