Subscribe Now Subscribe Today
Science Alert
 
FOLLOW US:     Facebook     Twitter
Blue
   
Curve Top
Journal of Applied Sciences
  Year: 2010 | Volume: 10 | Issue: 5 | Page No.: 413-418
DOI: 10.3923/jas.2010.413.418
Thermal Performance of a Two-Phase Closed Thermosyphon for Waste Heat Recovery System
M. Kannan and E. Natarajan

Abstract:
Performance study of a two phase closed thermosyphon was experimentally investigated. The experiments were carried out for different filling ratios of 30 to 90% with input heat transfer rates of 0 to 1000 W and for various working fluids such as distilled water, ethanol, methanol and acetone. Investigations were focused to find the influence of the filling ratio, maximum heat transport capability for various working fluids in a vertical two phase closed thermosyphon. The maximum heat transport capability was found to be high for water compared to other fluids such as ethanol, methanol and acetone, at the operating temperatures higher than 40°C.
PDF Fulltext XML References Citation Report Citation
How to cite this article:

M. Kannan and E. Natarajan, 2010. Thermal Performance of a Two-Phase Closed Thermosyphon for Waste Heat Recovery System. Journal of Applied Sciences, 10: 413-418.

DOI: 10.3923/jas.2010.413.418

URL: https://scialert.net/abstract/?doi=jas.2010.413.418

 