ABSTRACT
In this study, a numerical method is presented to solve the laminar flow forced convection in combined entry length of annular duct. The fluid viscosity has been taken as a function of temperature. The governing equations which have the elliptic nature are solved in coupled form by successive over-relaxation finite difference method. A feature of this scheme is the easy implementation of solid boundary conditions. A FORTRAN code is written for all the simulation processes. The fluid having Prantdl numbers ranging from 0.01 to 10 are considered. Comprehensive comparisons were made between the results of present method and available data, in which good agreement would exist.
PDF Abstract XML References Citation
How to cite this article
DOI: 10.3923/ajaps.2008.304.315
URL: https://scialert.net/abstract/?doi=ajaps.2008.304.315
INTRODUCTION
Heat exchangers with double-pipe configuration have tremendous applications in industry. To calculate the heat transfer coefficient in double-pipe heat exchangers, empirical correlations are used which is applicable only for one-side annulus.
In three-fluid heat exchangers, in which one of the fluids flows in annular passage, for calculation of the heat transfer surface, the convection coefficient is required. At the entrance region, local Nusselt number starts to decrease intensively and reaches its minimum value at the end of thermal entry length.
As reported in the references, heat exchangers are designed by using fully-developed flow equations. Therefore, for all exchangers, especially for multi-pass ones, in which fluid flows through entry region of each pass, calculated heat transfer surface becomes over design.
Also, when properties of fluids intensively depend on temperature, heat transfer coefficient varies nonlinearly through the passage and usually wall heat flux is not constant. Therefore, it is necessary to calculate local Nusselt number as a function of passage length and other characteristics. So, the best approach is to solve equations continuously and consecutively on the longitudinal elements.
Heaton et al. (1964) and Kays and London (1984) have studied the heat transfer problem in annular duct for laminar flow with constant properties in combined entry length. By Langhaars (1951) method, the momentum integral equation is solved for the hydrodynamic entry length.
This method was applicable for constant wall heat flux and the results have been obtained by assuming one wall with heat exchange and the other as insulated. For heat exchange at both walls the results of linearized momentum and energy equations by use of superposition principle was applied.
Sellars et al. (1956) solved the differential energy equation by separation of variables and changing the constant wall temperature to constant wall temperature gradient the flow in smooth circular tubes with varying heat flux along the tube axis and considered Re.Pr>100 in which the effect of axial heat conduction is ignorable. So, strum-liouville type differential equation has been obtained, so divided whole surface to longitudinal elements with constant heat flux and for each element came up by Stieltjes integral, then entered the flux continuous variation part to the Reimann integral and converted the discontinuous variation part to a summation because this integral was not solvable analytically.
This summation and integral can be solved analytically just on surfaces with simple temperature distribution. It is clear that this simplifying method is complicated and according to several assumptions the results can not be reliable.
Lundberg et al. (1972) and Kays et al. (2004) presented an analytical method for laminar flow with constant properties in annular duct with unequal heating conditions and solved the problem for fully developed flows separately. By using correlated parameters with diameters ratio in simplified momentum equation to one-dimensional laminar and developed flow from circular tubes and applying congruous limits to integration equation, the velocity profile in annular duct was gotten and by putting it in the energy equation for developed flow and according to this principle that the appointed heat flux from each surface, the temperature gradient on surface was specified and energy equation was integrated directly. In order to provide the heat exchanging boundary conditions from the surface in energy equation two special forms was necessary. Heating from outer surface of annulus as the inner one is insulated and the other one is: Heating from inner surface of annulus as the outer one is insulated.
The linearized energy equation lead to calculation of integral of both cases and for unequal heating via walls superposition principle was applied.
It is obvious that previous solutions used some simplifying assumptions so the results were not accurate enough. This study presents a full numerical method for forced convection heat transfer of laminar flow which uses elliptical differential equations.
GOVERNING EQUATIONS
For incompressible steady state laminar flow in annular duct with heat transfer because of duct symmetry Navier-Stokes equations in cylindrical coordinate, introducing stream function (ψ) which satisfy continuity equation, vorticity has been obtained as below:
(1) |
(2) |
Introducing hydraulic radius as:
and velocity (V), which is equal to inlet uniform velocity the variables and vorticity would be non-dimensionalized as below:
(3) |
From now on the asterisk sign will be dropped. So non-dimensional vorticity equation will be as:
(4) |
And so on for temperature:
where, To and Tw are inlet and wall temperature, respectively. So, non-dimensional energy equation is:
(5) |
(6) |
Assumptions
• | The fluid properties as density, specific heat and thermal conductivity are temperature independent: |
ρ = Const. Cp = Cont. K = Const. |
• | There is no energy source: |
• | For probability of high viscosity fluids, dissipation (ΦV) is used |
• | Temperature and velocity distribution are axisymmetric |
μ = μ(T) |
To avoid complexity of nonlinear partial differential equations, at first viscosity considered constant and then obtained temperature distribution is used to define grid viscosity value in order to correct velocity and temperature values, iteratively.
Used non-dimensional groups and temperature difference are:
(7) |
DISCRETIZED EQUATIONS
Central difference is used for interior nodes, hence discretized form of Eq. (2, 5) are:
(8) |
(9) |
Fig. 1: | A part of grid |
(10) |
(11) |
(12) |
(13) |
According to Fig. 1, the longitudinal and radial increments are assumed equal (Δx = Δr) and cell Reynolds and Peclet numbers (Arpaci and Larsen, 1984, Minkowycz et al., 1988) are defined as:
Results independency of grid is related to cell Reynolds number. For example for 30 nodes in radius direction and Re = 780, cell Reynolds number will be Rec = 0.05, thereafter increasing number of nodes has no effect on results.
BOUNDARY CONDITIONS
Non-dimensionalized boundary conditions are:
Inflow Conditions (x = 0):
(14) |
(15) |
(16) |
(17) |
Outflow Conditions (x = 1):
According to White (2005):
(18) |
(19) |
Where:
(20) |
(21) |
(22) |
(23) |
Solid Boundary Conditions
(24) |
For r = ro:
(25) |
For r = ri :
(26) |
Table 1: | Initial conditions for water, air and mercury flows |
Table 2: | Viscosity as a function of temperature for water, air and mercury |
NUMERICAL SCHEME
To solve system of elliptic equations in finite difference form, the point successive over relaxation method is chosen because of its fast convergence (Chung, 2002; Parshant, 2000). Over relaxation parameter (α) and also relaxation value is used instead of explicitly calculated values to control the convergence (Apaci and Larsen, 1984; Roache, 1976).
(27) |
where, is obtained from previous iteration.
To speed up the convergence the over relaxation parameter lies in the range of 1 ≤ αopt ≤ 2. Its optimized value is calculated as (Bejan, 1984; Nakamura, 1991):
(28) |
INITIAL CONDITIONS
Initial conditions are shown in Table 1.
The viscosity (kg m sec-1) is given by Reid et al. (1988) and Schmidt et al. (1984) as shown in Table 2.
In order to compare results of present study with others, eight non-dimensional lengths are chosen:
(29) |
RESULTS AND DISCUSSION
The results of present study and Kays et al. (2004) are shown in diagrams. Nuo and Nui by Kayss et al. (2004) method are given:
(30) |
Nuii | ≡ | Nusselt number when outer surface is insulated |
Nu∞ | ≡ | Nusselt number when inner surface is insulated |
Zo and Zi are correction factors related to Prandtl number and non-dimensional length. Also to match the curves the following coordinate conversion is used:
(31) |
Regarding Fig. 2, from the Kayss et al. (2004) data the Nuo curves for Pr = 1,0.7 after x = 0.2 approaches to a constant and same value, but for Pr = 0.01 with considerable difference reaches a higher value. Because the molten metal have great conductivity and during the thermal entry length in which temperature gradient is considerable along the flow direction the longitudinal heat conduction effect, especially in the laminar flow and for the Pe<50, is important and effective (Ozisik, 1988).
Here according to the input temperature Pe 10.5, so it will decrease the local Nusselt number along the entry length. In Kayss et al. (2004) method because of linearization of conservation equations this effect hasnt been considered so Kayss et al. (2004) data show higher Nusselt number.
Figure 5 for Kayss et al. (2004) data shows that when, Pr = 0.01 Nusselt number is higher than two other fluids, because air and water flows have Pe>50, so longitudinal heat transfer is ignorable. But in this study according to Fig. 3 and 4 for Nuo and Fig. 6 and 7 for Nu, the curves are converged to one specific value for all three Prantdl numbers because conservation equations are solved considering longitudinal heat transfer.
Fig. 2: | Local Nuo versus x+ for different Pr from the Kays data |
Fig. 3: | Local Nuo versus x+ for different Pr from the Fluent data |
Fig. 4: | Local Nuo versus x+ for different Pr from the present study data |
Fig. 5: | Local Nui versus x+ for different Pr from the Kays data |
Fig. 6: | Local Nui versus x+ for different Pr from the present study data |
Figure 8-10 shows that curves of Nuo, calculated by different methods, are approximately equal for all three prentdl numbers.
From Fig. 11-13, it is concluded that Nui curves of present study is only decreasing but by Kayss et al. (2004) data, at first it decreases and then begins to increase.
Fig. 7: | Local Nui versus x+ for different Pr from the present study data |
Fig. 8: | Nuo comparison among three method at Pr = 10 |
Fig. 9: | Nuo comparison among three method at Pr = 0.70 |
Kayss et al. (2004) method has no results for Pr = 0.01 and x<0.02, because he has used Langhaars (1951) approximation so truncated series, in addition neglected longitudinal heat conduction that led to considerable error.
Remember that these differences between present study and Kays et al. (2004) method are limited to:
in other cases the results are the same.
Fig. 10: | Nuo comparison among three method at Pr = 0.01 |
Fig. 11: | Nuo comparison among three method at Pr = 10 |
Fig. 12: | Nuo comparison among three method at Pr = 0.7 |
Fig. 13: | Nuo comparison among three method at Pr = 0.01 |
Two basic assumptions of Kayss et al. (2004) method is considering the viscosity constant and using specified heat fluxes but this study assumes viscosity as a function of temperature and is applicable for all symmetric boundary conditions.
CONCLUSION
Present study has more accurate results in comparison with Kayss et al. (2004) data, because:
• | Viscosity is assumed as a function of temperature |
• | Longitudinal heat conduction is considered |
• | Elliptic differential conservation equations are solved in coupled form. |
• | It is suitable for all types of boundary conditions, at last it is applicable for varying boundary conditions along the tube |
• | In spite of Kayss et al. (2004) method this study is full numeric and more simple |
NOMENCLATURE
Cp | = | Specific heat at constant pressure |
Dh | = | Hydraulic diameter |
Ec | = | Eckert number |
k | = | Thermal conductivity |
LH | = | Hydrodynamic entry length |
Nuoo | = | Nusselt number when outer wall is isolated |
Nuii | = | Nusselt number when inner wall is isolated |
Nuo | = | Nusselt number at outer wall |
Nui | = | Nusselt number at inner wall |
Pe | = | Pecklet number |
Pec | = | Cell Pecklet number |
Pr | = | Prantdl number |
rh | = | Hydraulic radius |
Re | = | Reynolds No. |
Rec | = | Cell Reynolds No. |
ro | = | Outer radius |
ri | = | Inner radius |
T | = | Bulk temperature |
Tw | = | Wall temperature |
To | = | Inlet bulk temperature |
= | Gratz No. | |
Zi, Zo | = | Influence coefficient for annulus heat transfer |
GREEK SYMBOLS
ψ | = | Stream function |
ω | = | Vorticity |
φv | = | Dissipation function |
ρ | = | Density |
α | = | Thermal diffusivity |
REFERENCES
- Heaton, H.S., W.C. Reynolds and W.M. Kays, 1964. Heat transfer in annular passages simultaneous development of velocity and temperature fields in laminar flow. Int. J. Heat Mass Transfer, 7: 763-781.
CrossRef - Kays, W.M., M.E. Crawford and B. Weigand, 2004. Convective Heat and Mass Transfer. 4th Edn., MC Graw-Hill, New York,ISBN-13: 978-0072468762, pp: 112-145.
Direct Link - White , F.M., 2005. Viscous Fluid Flow. 3rd Edn., MC Graw-Hill, New York,ISBN-10: 0072402318, pp: 76-81.
Direct Link